Based on this case series, all teeth, and particularly the incisors, should be examined for signs of gingivitis and hypercementosis and subsequently radiographed for an early diagnosis and management. When compared with our hospital population, older geldings were more likely to be affected with cementoma formation and its accompanying resorptive process. Removal of clinically and radiographically affected teeth carries a good prognosis for improved quality of life.
BackgroundBlood pressure is relevant to the diagnosis and management of many medical, cardiovascular and critical diseases. The accuracy of many commonly used noninvasive blood pressure (NIBP) monitors and the accuracy of NIBP measurements in hypo‐ and hypertensive standing horses has not been determined.Hypothesis/ObjectivesThe objective of this study was to investigate the accuracy of an oscillometric BP monitor in standing horses before and during pharmacologically induced hyper‐ and hypotension and to compare results in standing and anesthetized horses.AnimalsEight standing mares from a research herd (SG) and eight anesthetized horses from a hospital population (AG).MethodsProspective experimental and observational studies. Invasive blood pressure (IBP) and NIBP, corrected to heart level, were measured simultaneously. In the SG hyper‐ and hypotension were induced by administration of phenylephrine (3 μg/kg/min IV for 15 minutes) and acepromazine (0.05 mg/kg IV), respectively. In the AG NIBP and IBP were recorded during regular hospital procedures.ResultsThere was a significant correlation between mean NIBP and IBP in standing (R = 0.88, P < .001) and anesthetized horses (R = 0.81, P < .001). The mean bias (lower, upper limit of agreement) was 16.4(−16.1, 48.9) mmHg for mean BP in the SG and 0.5(−22.3, 23.2) mmHg in the AG. The NIBP device was capable of identifying the increase and decrease in BP in all horses, but in the SG significant correlation between NIBP and IBP was only detected for the normotensive phase.Conclusion and Clinical ImportanceWhile the evaluated oscillometric BP device allowed estimation of BP and adequately differentiated marked trends, the accuracy and precision were low in standing horses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.