Background and study aims Endoscopic ultrasound (EUS)-guided tissue sampling is the standard of care for diagnosing solid pancreatic lesions. While many two-way comparisons between needle types have been made in randomized controlled trials (RCTs), it is unclear which size and type of needle offers the best probability of diagnosis. We therefore performed a network meta-analysis (NMA) to compare different sized and shaped needles to rank the diagnostic performance of each needle.
Methods We searched MEDLINE, EMBASE and Cochrane Library databases through August, 2020 for RCTs that compared the diagnostic accuracy of EUS fine-needle aspiration (FNA) and biopsy (FNB) needles in solid pancreatic masses. Using a random-effects NMA under the frequentist framework, RCTs were analyzed to identify the best needle type and sampling technique. Performance scores (P-scores) were used to rank the different needles based on pooled diagnostic accuracy. The NMA model was used to calculate pairwise relative risk (RR) with 95 % confidence intervals.
Results Review of 2577 studies yielded 29 RCTs for quantitative synthesis, comparing 13 different needle types. All 22G FNB needles had an RR > 1 compared to the reference 22G FNA (Cook) needle. The highest P-scores were seen with the 22G Medtronic FNB needle (0.9279), followed by the 22G Olympus FNB needle (0.8962) and the 22G Boston Scientific FNB needle (0.8739). Diagnostic accuracy was not significantly different between needles with or without suction.
Conclusions In comparison to FNA needles, FNB needles offer the highest diagnostic performance in sampling pancreatic masses, particularly with 22G FNB needles.
Background The difference in clinical outcomes after endoscopic submucosal dissection (ESD) and endoscopic mucosal resection (EMR) for early Barrett's esophagus (BE) neoplasia remains unclear. We compared the recurrence/residual tissue rates, resection outcomes, and adverse events after ESD and EMR for early BE neoplasia.
Methods We included patients who underwent EMR or ESD for BE-associated high grade dysplasia (HGD) or T1a esophageal adenocarcinoma (EAC) at eight academic hospitals. We compared demographic, procedural, and histologic characteristics, and follow-up data. A time-to-event analysis was performed to evaluate recurrence/residual disease and a Kaplan–Meier curve was used to compare the groups.
Results 243 patients (150 EMR; 93 ESD) were included. EMR had lower en bloc (43 % vs. 89 %; P < 0.001) and R0 (56 % vs. 73 %; P = 0.01) rates than ESD. There was no difference in the rates of perforation (0.7 % vs. 0; P > 0.99), early bleeding (0.7 % vs. 1 %; P > 0.99), delayed bleeding (3.3 % vs. 2.1 %; P = 0.71), and stricture (10 % vs. 16 %; P = 0.16) between EMR and ESD. Patients with non-curative resections who underwent further therapy were excluded from the recurrence analysis. Recurrent/residual disease was 31.4 % [44/140] for EMR and 3.5 % [3/85] for ESD during a median (interquartile range) follow-up of 15.5 (6.75–30) and 8 (2–18) months, respectively. Recurrence-/residual disease-free survival was significantly higher in the ESD group. More patients required additional endoscopic resection procedures to treat recurrent/residual disease after EMR (EMR 24.2 % vs. ESD 3.5 %; P < 0.001).
Conclusions ESD is safe and results in more definitive treatment of early BE neoplasia, with significantly lower recurrence/residual disease rates and less need for repeat endoscopic treatments than with EMR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.