This paper describes detection of cracks in ceramic tableware using a portable digital holographic camera working on the principle of double-exposure digital holographic interferometry. Digital image processing techniques are applied on amplitude and phase information obtained from the numerically reconstructed wavefronts of the test object to locate position of the defect. Speckles generated due to illumination of the rough surface of the ceramic cup with the coherent light source deteriorate quality of the interferometric phase. Several iterations of the averaging filter with optimized kernel size are applied on sine and cosine components of the interferometric phase to minimize the speckle noise. The effect of kernel size of the matrix used in the averaging filter on quality of the interferometric phase is analyzed by evaluating the signal-to-noise ratio. The experimentally obtained size of crack on a ceramic cup (0.08 mm) is validated by a mechanical profiler with an error of 6.6%. This study may help in improving the quality criteria of tableware items.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.