ObjectivesIn intraarticular distal humerus fractures, internal fixation with double plates is the gold standard treatment. However the optimal plate configuration is not clear in the literature. The aim of this study was to compare the biomechanical stability of the parallel and the orthogonal anatomical locking plating systems in intraarticular distal humerus fractures in artificial humerus models.MethodsIntraarticular distal humerus fracture (AO13-C2) with 5 mm metaphyseal defect was created in sixteen artificial humeral models. Models were fixed with either orthogonal or parallel plating systems with locking screws (Acumed elbow plating systems). Both systems were tested for their stiffness with loads in axial compression, varus, valgus, anterior and posterior bending. Then plastic deformation after cyclic loading in posterior bending and load to failure in posterior bending were tested. The failure mechanisms of all the samples were observed.ResultsStiffness values in every direction were not significantly different among the orthogonal and the parallel plating groups. There was no statistical difference between the two groups in plastic deformation values (0.31 mm–0.29 mm) and load to failure tests in posterior bending (372.4 N–379.7 N). In the orthogonal plating system most of the failures occurred due to the proximal shaft fracture, whereas in the parallel plating system failure occurred due to the shift of the most distal screw in proximal fragment.ConclusionOur study showed that both plating systems had similar biomechanical stabilities when anatomic plates with distal locking screws were used in intraarticular distal humerus fractures in artificial humerus models.
Scoring systems and the ischemic time are not the only predictors of amputation. The decision of the treatment mode should be made by the patient and the care team after discussing the options and outcomes rather than relying on a scoring system.
Distraction interposition arthroplasty is a salvage procedure which appears to have good long-term functional results, especially in patients in which elbow arthroplasty is not suitable. The use of Achilles allograft for interposition can protect the joint space in the long-term.
HighlightsThe main goal of the treatment is the anatomical reduction of the ulna fracture and the radial head dislocation in acute and chronic Monteggia cases.The most commonly preferred technique is open reduction with ulnar osteotomy.The radiocapitellar joint is very sensitive to ulna length.To decide whether to repair or reconstruct the annular ligament remains controversial.Anatomic and stable restoration of radiocapitellar joint by correcting ulna deformity may be performed.
The purpose of this study was to present the case report of a 7-year-old patient who was treated with hip arthroscopy for an acetabular osteoid osteoma. A 7-year-old patient was referred to our clinic with hip pain. In the assessment of the patient, an acetabular osteoid osteoma was detected in his right hip; it was adjacent to his triradiate cartilage. An arthroscopic surgery was planned as an alternative to open safe hip dislocation. The osteoid osteoma was completely removed with hip arthroscopy. Postoperative CT scanning and histopathological analysis confirmed the diagnosis. Exposure of the acetabulum can be problematic in paediatric patients due to the potential risks of open safe dislocation. Hip arthroscopy can safely be used for benign hip lesions in paediatric patients. Level of evidence Case report, Level V.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.