Implantable intramedullary nail lengthening devices (e.g., PRECICE 2 system) have been proposed as alternative method to external fixation for lower limb lengthening surgery. The aim of this study was to analyse our outcomes and complications using the PRECICE 2 (P2) nail system and review them in light of the existing literature. A retrospective multicentre study was conducted on patients <18 years, who were treated for limb lengthening using the P2 system. The inclusion criteria were a limb length discrepancy ≥ 30 mm and a follow-up ≥6 months after the end of treatment. A total of 26 (15 males) patients were included, average age was 14.7 ± 2.3 years; 26 nails (21 femur, 5 tibia) were implanted. The average goal lengthening was 49.4 ± 12.4 mm, while average achieved lengthening was 44.4 ± 11.6 mm. Average distraction and consolidation indexes were 11.9 ± 2.1 days/cm and 25.1 ± 8.1 days/cm, respectively. Nail accuracy and reliability were 91.1% and 88.5%, respectively. A total of five problems (joint contractures), one obstacle (femur fracture) and three complications (hip joint subluxation, deep infection and nail running back) were encountered. The P2 nail system is a valid alternative to external fixator for limb lengthening in young patients with no significant angular or rotation deformities. Our study confirms a favourable complication rate and available evidence from literature suggests a lower complication rate than external fixator systems. Nevertheless, surgeons should keep a watchful eye on risk of joint subluxation and mechanical complications with intramedullary lengthening.
Many variables are involved in hydroxyapatite coating of metals by plasma-spray techniques. The authors have investigated the biological response to some of the most relevant variables in a controlled in vivo trial. The bone response in the rabbit towards hydroxyapatite coated cylinders was studied keeping the following variables fixed: (a) crystallinity of coating (greater than 90% and between 70% and 60%); (b) thickness of coating (50 and 100 gm); (c) metallic substrate (titanium alloy and duplex stainless steel). Analysis of the results highlights the importance of defining the crystallinity of the coating to forecast its in vivo behaviour: highly crystalline coating is more stable in time but can give rise to fragmented bulky particles; a less crystalline coating is subject to slow degradation in the long term but facilitates its substitution by newly formed bone. Furthermore, it has been found that no relevant differences carl be ascribed to a variation in coating thickness between 50 and 100 gm. It has, also, been observed that there are no differences when duplex stainless steel is used instead of titanium alloy as metallic substrate, confirming that bone responds primarily to the coating.
Postoperative drainage after total knee arthroplasty (TKA) is an established routine procedure for orthopedic surgeries, and is considered a useful practice in postoperative, but the use of drainage is controversial. Our study aims to clarify this aspect of knee prosthetic surgery. A systematic review of the literature was performed in the electronic databases to investigate the risks and the benefits of wound drainage in total knee arthroplasty: 30 articles were included in our review for eligibility. After the analysis of the literature performed, we found no significant advantages related with the use of wound drain following total knee replacement (TKR) in terms of pain, transfusion rate, blood loss, swelling, postoperative range of motion, wound complications, deep infection and hospital stay, while no drainage means a significant cost saving compared to drainage use. Thus, the use of drainage after TKA cannot be justified on the basis of the results of this study.
Elbow stiffness is defined as any loss of movement that is greater than 30° in extension and less than 120° in flexion. Causes of elbow stiffness can be classified as traumatic or atraumatic and as congenital or acquired. Any alteration affecting the stability elements of the elbow can lead to a reduction in the arc of movement. The classification is based on the specific structures involved (Kay’s classification), anatomical location (Morrey’s classification), or on the degree of severity of rigidity (Vidal’s classification). Diagnosis is the result of a combination of medical history, physical examination (evaluating both active and passive movements), and imaging. The loss of soft tissue elasticity could be the result of bleeding, edema, granulation tissue formation, and fibrosis. Preventive measures include immobilization in extension, use of post-surgical drain, elastic compression bandage and continuous passive motion. Conservative treatment is used when elbow stiffness has been present for less than six months and consists of the use of serial casts, static or dynamic splints, CPM, physical therapy, manipulations and functional re-education. If conservative treatment fails or is not indicated, surgery is performed. Extrinsic rigidity cases are usually managed with an open or arthroscopic release, while those that are due to intrinsic causes can be managed with arthroplasties. The elbow is a joint that is particularly prone to developing stiffness due to its anatomical and biomechanical complexity, therefore the treatment of this pathology represents a challenge for the physiotherapist and the surgeon alike.
Background Femoral neck fractures (FNF) are one of the most common injury in the elderly. A valid radiographic classification system is mandatory to perform the correct treatment and to allow surgeons to facilitate communication. This study aims to evaluate reliability of 2018 AO/OTA Classification, AO/OTA simplified and Garden classification. Methods Six Orthopaedic surgeons, divided in three groups based on trauma experience, evaluated 150 blinded antero-posterior and latero-lateral radiography of FNF using Garden classification, 2018 AO/OTA and simplified AO/OTA classification. One month later, the radiographs were renumbered and then each observer performed a second evaluation of the radiographs. The Kappa statistical analysis was used to determine the reliability of the classifications. Cohen’s Kappa was calculated to determine intra and inter observer reliability. Fleiss’ Kappa was used to determine multi-rater agreement. Results The k values of interobserver reliability for Garden classification was from 0,28 to 0,73 with an average of 0,49. AO classification showed reliability from 0,2 to 0,42, with average of 0,30. Simplified AO/OTA classification showed a reliability from 0,38 to 0,58 with an average of 0,48. The values of intra observer reliability for Garden classification was from 0,48 to 0,79 with an average of 0,63. AO classification showed reliability from 0,2 to 0,64 with an average of 0,5. Simplified AO/OTA classification showed a reliability from 0,4 to 0,75 with an average of 0,61. Conclusion The revised 2018 AO/OTA classification simplified the previous classification of intracapsular fracture but remain unreliable with only fair interobserver reliability. The simplified AO/OTA classification show a reliability similar to Garden classification, with a moderate interobserver reliability. The experience of the surgeons seems not to improve reliability. No classification has been shown to be superior in terms of reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.