This report describes the construction and properties of a Ge(Li) bore hole probe for in situ gamma ray spectrometry. The probe has the form of a cylinder 8.9 cm in diameter and 160 cm long. It contains a 22 cm3 coaxial Ge(Li) detector, cooled by liquid nitrogen. Holding time of the assembled probe is in excess of ten hours, energy resolution is 2.3 keV for 122 keV photons and 2.6 keV for 1333 keV photons.
The probe has been used in field experiments in the Ranstad uranium mine and for the study of neutron activation spectra obtained in bore hole models. Results from these experiments are presented and discussed. It is stressed that the Ge(Li) probe gives promise to become a powerful tool in bore hole activation analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.