A number of studies have highlighted physiological data from the first surge in critically unwell Covid-19 patients but there is a paucity of data describing emerging variants of SARS-CoV-2, such as B.1.1.7. We compared ventilatory parameters, biochemical and physiological data and mortality between the first and second COVID-19 surges in the United Kingdom, where distinct variants of SARS-CoV-2 were the dominant stain. We performed a retrospective cohort study investigating critically unwell patients admitted with COVID-19 across three tertiary regional ICUs in London, UK. Of 1782 adult ICU patients screened, 330 intubated and ventilated patients diagnosed with COVID-19 were included. In the second wave where B.1.1.7 variant was the dominant strain, patients were had increased severity of ARDS whilst compliance was greater (p<0.05) and d-dimer lower. The 28-day mortality was not statistically significant (1st wave: 42.2% vs 2nd wave: 39.8%). However, when adjusted for key covariates, the hazard ratio for 28-day mortality in those patients with B.1.1.7 was 3.79 (CI 1.04–13.8; p = 0.043) compared to the original strain. During the second surge in the UK, where the COVID-19 variant B.1.1.7 was most prevalent, significantly more patients presented to critical care with severe ARDS. Furthermore, mortality risk was significantly greater in our ICU population during the second wave of the pandemic in those patients with B.1.1.7. As ICUs are experiencing further waves (particularly by the delta (B.1.617.2) variant), we highlight the urgent need for prospective studies describing immunological and pathophysiological differences across novel emerging variants.
Two respiratory registrars with level 1 ultrasound competency aimed to set up a service to provide supervised pleural procedures training for trainees at a district general hospital.
A 31-year-old female was referred with a history of unexplained exertional breathlessness. The patient had normal resting lung function and a CT thorax showed no significant abnormality. Closer scrutiny of the flow-volume loop confirmed an elevated Empey's index. Cardiopulmonary exercise testing with continuous laryngoscopy was conducted to evaluate the upper airway response to exercise which confirmed loud biphasic wheeze. A bronchoscopy revealed no stenosis nor intraluminal narrowing, however, a contrast CT confirmed a right-sided aortic arch and aberrant left subclavian artery. Following multidisciplinary review, the patient opted for a surgical approach to treatment however despite initially reporting an improvement in symptoms and exercise capacity continued to suffer exertional wheeze two-years post-surgery. This clinical report describes a rare vascular cause of exertional wheeze but also provides a cautionary note in terms of providing a guarded prognosis for adults undergoing surgical intervention for tracheal compression arising from congenital vascular abnormalities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.