This protocol describes how to prepare and image human fetuses by microfocus computed tomography, a less invasive imaging alternative to conventional autopsy. TWEET Non-invasive autopsy of human fetuses using microfocus computed tomography @ian_simcock COVER TEASER Microfocus computed tomography of human fetuses RELATED LINKS
High-quality research is essential in guiding evidence-based care, and should be reported in a way that is reproducible, transparent and where appropriate, provide sufficient detail for inclusion in future meta-analyses. Reporting guidelines for various study designs have been widely used for clinical (and preclinical) studies, consisting of checklists with a minimum set of points for inclusion. With the recent rise in volume of research using artificial intelligence (AI), additional factors need to be evaluated, which do not neatly conform to traditional reporting guidelines (eg, details relating to technical algorithm development). In this review, reporting guidelines are highlighted to promote awareness of essential content required for studies evaluating AI interventions in healthcare. These include published and in progress extensions to well-known reporting guidelines such as Standard Protocol Items: Recommendations for Interventional Trials-AI (study protocols), Consolidated Standards of Reporting Trials-AI (randomised controlled trials), Standards for Reporting of Diagnostic Accuracy Studies-AI (diagnostic accuracy studies) and Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis-AI (prediction model studies). Additionally there are a number of guidelines that consider AI for health interventions more generally (eg, Checklist for Artificial Intelligence in Medical Imaging (CLAIM), minimum information (MI)-CLAIM, MI for Medical AI Reporting) or address a specific element such as the ‘learning curve’ (Developmental and Exploratory Clinical Investigation of Decision-AI) . Economic evaluation of AI health interventions is not currently addressed, and may benefit from extension to an existing guideline. In the face of a rapid influx of studies of AI health interventions, reporting guidelines help ensure that investigators and those appraising studies consider both the well-recognised elements of good study design and reporting, while also adequately addressing new challenges posed by AI-specific elements.
BACKGROUND: Noninvasive imaging autopsy alternatives for fetuses weighing <500 grams are limited. Microfocus computed tomography has been reported as a viable option in small case series with the potential to avoid an invasive autopsy. Implementation of postmortem microfocus computed tomography in a large cohort as part of routine clinical service has yet been unreported, and realistic "autopsy prevention rates" are unknown. OBJECTIVE: This study aimed to describe the range of abnormalities detectable on fetal microfocus computed tomography in a clinical setting and additional findings identified on the antenatal ultrasound and to estimate the invasive autopsy avoidance rate (ie, cases in which imaging was sufficient to deem autopsy unnecessary). STUDY DESIGN: A prospective observational case series of all fetuses referred for microfocus computed tomography imaging at a single institution was conducted for 3 years (2016e2019). Imaging was reported by 2 pediatric radiologists before autopsy, with "decision to proceed" based on the specialist perinatal pathologists' judgment and parental consent. Agreement rates between microfocus computed tomography and antenatal ultrasound were evaluated, and where feasible, diagnostic accuracy for microfocus computed tomography was calculated using autopsy as a reference standard. RESULTS: A total of 268 fetuses were included (2e350 grams body weight; 11e24 weeks' gestation), with cause for demise in 122 of 268 (45.5%). Of the 122 fetuses, 64 (52.5%) exhibited fetal anomalies. Although 221 of 268 (82.5%) fetuses had consent for invasive autopsy, only 29 of the 221 (13.1%) underwent this procedure, which implied an autopsy avoidance rate of 192 of 221 (86.9%). Complete agreement was present for all brain, thoracic, and abdominal pathologies, whereas sensitivity and specificity for cardiac anomalies were 66.7% and 91.7%, respectively. Microfocus computed tomography and antenatal ultrasound agreement was found in 219 of 266 cases (81.9%), with partial agreement in 21 of 266 (7.9%) and disagreement in 26 of 266 (10.5%), mostly because of additional cardiac, soft tissue, or genitourinary findings by microfocus computed tomography, which were not seen on the ultrasound. CONCLUSION: Fetal microfocus computed tomography imaging is a viable and useful tool for imaging early gestational fetuses and can avoid the need for invasive autopsy. Confirmation of antenatal diagnoses is achieved in most cases, and additional anomalies may also be detected.
Non-radiologist point-of-care ultrasonography (US) is increasingly implemented in paediatric care because it is believed to facilitate a timely diagnosis, such as in ascites or dilated renal pelvicalyceal systems, and can be used to guide interventional procedures. To date, all policy statements have been published by non-radiologic societies. The European Society of Paediatric Radiology hereby issues a position statement on paediatric non-radiologist point-of-care US from the point of view of those leading on children’s imaging, i.e. paediatric radiologists. In this position statement, we will address the boundaries, education, credentialing, quality control, reporting and storage of images in paediatric practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.