This paper reports the effect of temperature distribution on tube rupture at the pulverized coal fired thermal power plant. A computational model was applied to a 150 MWe boiler burning high-ash, medium-volatile coal. The radial and axial flame temperature distribution in the boiler was simulated using CFD code FLUENT. Flame temperatures were measured at points close to wall in some boiler levels and compared with computational fluid dynamics (CFD) solutions. CFD analysis showed that the flame shaped in the centre of the boiler and the temperature decreased gradually towards the boiler walls. The coal and ash composition was analyzed, and tube thickness was measured. Analysis showed that the ash and chlorine content of the coal, and SiO 2 content of the ash were very high. Deposits on tubes can occur overheating, fouling and slagging which lead to tube ruptures. The abrasive effect of the ash accelerated thinning of the tubes and caused them to rupture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.