In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.
Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct apical access in eight porcine hearts. A clinical stentless bioprosthetic valve affixed to a platinum stent was compressed onto a balloon-tipped catheter. This was fed through a 15-18-mm delivery port inserted into the left ventricular (LV) apex via a minimally invasive subxyphoid incision. Using interactive real-time MRI, the surgeon implanted the prosthetic valve in the correct location at the aortic annulus within 90 s. In four of the animals immediately after implantation, ventricular function, blood flow through the valve, and myocardial perfusion were evaluated with MRI. MRI-guided beating-heart surgery may provide patients with a less morbid and more durable solution to structural heart disease. Recently there has been a focus on using minimally invasive approaches in cardiac surgery in an effort to reduce trauma and speed recovery for the patient (1-3). In valve surgery, incisions have been shortened and robotics employed to achieve this goal; however, these approaches still require arresting and emptying of the heart to allow visualization. Real-time MRI techniques previously developed for intravascular guidance (4,5) are immediately applicable to provide vision in the surgical field, even in a beating heart with circulating blood, to guide the surgeon.A new generation of short (120 cm), wide-bore (70 cm) 1.5T imaging systems (Magnetom Espree, Siemens Medical Solutions) has recently been introduced. This magnet design gives a clearance of up to 30 cm above the chest of the supine patient, and the short design allows a surgeon to directly manipulate thoracoscopic instruments within the chest with ample "attack angles" and degrees of freedom. The more open bore allows better access to the patient for anesthesia when imaging the heart. While MRguided therapeutic interventions have been pursued extensively (6,7), most MR systems used in these applications to date have not been designed for the highperformance real-time scanning required for guiding cardiac procedures. The imaging gradients and amplifiers of the new systems yield a scanning performance that rivals that of the standard cardiac MR scanners, and therefore high-quality images can be obtained with real-time acquisition speeds. Imaging techniques used for intravascular MR guidance are immediately applicable to minimally invasive surgical procedures. The excellent blood/tissue contrast and the ability to interactively adjust imaging planes to view devices and the beating heart from multiple simultaneous viewpoints makes real-time MR ideal for guiding cardiac surgical interventions.The key to any interventional treatment is achieving the correct balance between risk and benefit. In the surgical treatment of aortic valve disease, the mo...
The often touted advantages of MR guidance remain largely unrealized for cardiovascular interventional procedures in patients. Many procedures have been simulated in animal models. We argue these opportunities for clinical interventional MR will be met in the near future. This paper reviews technical and clinical considerations and offers advice on how to implement a clinical-grade interventional cardiovascular MR (iCMR) laboratory. We caution that this reflects our personal view of the "state of the art."
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.