This study showed that syndesmosis fixation at the level of 30-40 mm above the tibiotalar joint has advantages with regard to stress in screws in comparison with the other evaluated levels.
BackgroundThe purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models.MethodsTwo different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew® (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew® FT II (CS FT II) 5.5 mm (without augmentation as used routinely).ResultsThe mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N.ConclusionsAugmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative.
Stress that occurs in syndesmotic screws is closely related to their geometry and dimensions. According to the results, a 3.5-mm cortical screw with the ideal screw design regarding optimal parameters to resist against stresses in the syndesmosis seems more reasonable to choose in syndesmotic fixation.
Background:Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur.Aims:To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis.Study Design:Biomechanical study.Methods:Computed tomography images of patients’ right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.