Several techniques for measuring the strain induced a9-martensite content in EN 1.4318 (AISI 301LN) and EN 1.4301 (AISI 304) austenitic stainless steels were compared in order to determine a correlation curve between Ferritescope measurement results and actual a9-martensite contents. The studied methods involved Satmagan measurement, magnetic balance measurement, X-ray diffraction, density measurement and quantitative optical metallography. Satmagan, magnetic balance and density measurements were found to give equal a9-martensite contents. X-ray diffraction results were affected by the texture but averaging of several diffraction peaks improved the reliability of the results. It was shown that a9-martensite can be detected by means of optical metallography, but quantitative analysis is time consuming and inaccurate. The relationship between the Ferritescope results and actual a9-martensite contents measured with the other techniques was found to be linear. According to the results, the Ferritescope readings can be converted to actual a9-martensite contents by multiplying with a correction factor of 1 . 7.MST/6120
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.