Commercial HIV-1 genotypic resistance assays are very expensive, particularly for use in resource-constrained settings like India. Hence a cost effective in-house assay for drug resistance was validated against the standard ViroSeq™ HIV-1 Genotyping System 2.0 (Celera Diagnostics, CA, USA). A total of 50 samples were used for this evaluation (21 proficiency panels and 29 clinical isolates). Known resistance positions within HIV-1 protease (PR) region (1-99 codons) and HIV-1 reverse-transcriptase (RT) region (1-240 codons) were included. The results were analysed for each codon as follows: (i) concordant; (ii) partially concordant; (iii) indeterminate and (iv) discordant. A total of 2750 codons (55 codons per patient sample × 50 samples) associated with drug resistance (1050 PR and 1700 RT) were analysed. For PR, 99% of the codon results were concordant and 1% were partially concordant. For RT, 99% of the codon results were concordant, 0.9% were partially concordant and 0.1% were discordant. No indeterminate results were observed and the results were reproducible. Overall, the in-house assay provided comparable results to those of US FDA approved ViroSeq™, which costs about a half of the commercial assay ($ 100 vs. $ 230), making it suitable for resource-limited settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.