Metallic foreign bodies have been re− moved under fluoroscopic control but this can be hazardous [1, 2]. We describe here an endoscopic method for removal of sharp metallic foreign bodies using a magnetic retrieval instrument we de− signed ourselves.After the trial was approved by the ethical committee and informed consent was ob− tained, ten patients who had ingested sharp foreign bodies were included in the study. Four people had ingested pins, four had ingested open safety pins, and two had ingested nails. Two were impacted and two were penetrating. Pentazocine (15 mg) and hyosine butylbromide (20 mg) were used as premedication. The time required, and the complication and failure rates were recorded.We used a stainless steel wire (200 cm in length, 0.75−mm thick) with two 7−mm− diameter magnetic discs with a strength of 0.17 tesla fixed at one end. A Teflon sheath (7 Fr, 160 cm) was used as a sleeve, and a ligator cylinder was used during for− eign−body retrieval (Figure 1). The cylin− der was fixed at the tip of the endoscope. The sheath was passed through the chan− nel to the tip of the endoscope. The wire end of the instrument was passed through the sheath so that the magnet was positioned at the tip of the endo− scope. As the endoscope reached the for− eign body, the magnet was pushed out and the foreign body stuck to the magnet. The foreign body and magnet were then drawn into the cylinder and the endo− scope was removed. All the foreign bodies were removed using this method without any complications in mean time of 68 sec− onds (range 46 ± 100 seconds).We used our instrument previously to re− move ferromagnetic coins [3, 4]. The sharp foreign bodies were light and so were attracted by the small magnet, and the pulling back of the magnet led to their disimpaction. Even the sharp foreign bod− ies that had penetrated could be pulled out because the head portion of the pins and safety pins could be visualized. The portion of the foreign body with a larger surface area had a tendency to stick to the magnet, meaning that the elongated sharp foreign bodies aligned themselves along their longitudinal axis (Figure 2). The sharp end of the foreign body fol− lowed the head, thus avoiding mucosal injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.