We have measured the differences between the Kelvin thermodynamic temperature and the temperature of the International Temperature Scale of 1990 on nine isotherms between the triple point of mercury and 380 K, by means of a primary acoustic thermometer. For the present measurements the standard uncertainty of (T − T 90 ) ranges from 0.9 mK at 234 K to 1.7 mK at 380 K. The experimental method is based on the measurement of the acoustic resonance frequencies of an argon-filled spherical cavity and the microwave resonance frequencies of the same cavity when evacuated. The present results agree within the remarkably small combined uncertainties with both NIST acoustic thermometry ([1]
In this paper, we specify the purpose of an international temperature scale and present some definitions that are basic to the International Temperature Scale of 1990. These definitions include those for non-uniqueness and for the temperature fixed points underlying the scale. Three types of non-uniqueness are identified.
The triple point of water serves to define the kelvin, the unit of thermodynamic temperature, in the International System of Units (SI). Furthermore, it is the most important fixed point of the International Temperature Scale of 1990 (ITS-90). Any uncertainty in the realization of the triple point of water contributes directly to the measurement uncertainty over the wide temperature range from 13.8033 K to 1234.93 K.The Consultative Committee for Thermometry (CCT) decided at its 21st meeting in 2001 to carry out a comparison of water triple point cells and charged the BIPM with its organization.Water triple point cells from 20 national metrology institutes were carried to the BIPM and were compared with highest accuracy with two reference cells. The small day-to-day changes of the reference cells were determined by a least-squares technique. Prior to the measurements at the BIPM, the transfer cells were compared with the corresponding national references and therefore also allow comparison of the national references of the water triple point.This report presents the results of this comparison and gives detailed information about the measurements made at the BIPM and in the participating laboratories. It was found that the transfer cells show a standard deviation of 50 µK; the difference between the extremes is 160 µK. The same spread is observed between the national references.The most important result of this work is that a correlation between the isotopic composition of the cell water and the triple point temperature was observed. To reduce the spread between different realizations, it is therefore proposed that the definition of the kelvin should refer to water of a specified isotopic composition.The CCT recommended to the International Committee of Weights and Measures (CIPM) to clarify the definition of the kelvin in the SI brochure by explicitly referring to water with the isotopic composition of Vienna Standard Mean Ocean Water (VSMOW). The CIPM accepted this recommendation and the next edition of the SI brochure will include this specification.Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
This is a summary of the Consultative Committee for Thermometry (CCT) Key Comparison CCT-K3, i.e. the comparison of realizations of the fixed points of the International Temperature Scale of 1990 (ITS-90) over the range 83.8058 K to 933.473 K. The differences in the realizations of the various fixed points in this range of the ITS-90 and the uncertainties of those differences are given for the fifteen standards laboratories participating in the comparison.
The freezing point of silver is being considered as a joining point between platinum resistance thermometry and optical pyrometry. Therefore the freezing points of high purity samples of silver have been investigated. An important impurity effect arises from the depression of the freezing point of pure Bg caused by residual dissolved oxygen contents in some samples. Melting range parameters were determined on both oxided and carefully deoxided samples to aid in the selection of the purest sample. In addition the presence of dissolved oxygen is indicated by a slope inversion on the melting curve. Evaluations of the freezing point depression for small oxygen contents are given. A graphite sample crucible, 11. ith graphite radiation and gettering discs interspersed in the thermal insulation of the thermometer well, is a convenient arrangement to prevent the contamination of the sample in the presence of traces of oxygen, but is not sufficient for purifying heavily oxided samples; such samples require a vacuum treatment at about 1050" C. The pressure effect on the freezing temperature of silver has been determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.