Clinical implementation of cone-beam tomography has been hampered by the lack of two-dimensional electronic x-ray detectors that can encompass the full width of the body. We encountered the undersized detector problem in our development of a cone-beam CT system for radiotherapy applications. In order to mitigate the problem, we developed an algorithm which permits an increased reconstruction volume to be imaged using a detector of a given size. We describe the algorithm and report on its implementation using a radiotherapy simulator configured with a digital fluorography unit.
An algorithm is described, based on ray-tracing and the beam's-eye-view, that exhaustively searches all permitted beam directions. The evaluation of the search is based on a general cost function that can be adapted to the clinical objectives by means of parameters and weighting factors. The approach takes into account the constraints of the linear accelerator by discarding beam directions that are not permitted. A sensitivity analysis was carried out to determine appropriate parameters for different sized organs, and a prostate case was used to benchmark the approach. The algorithm was also applied to two clinical cases (brain and sinus) to test the benefits of the approach compared with manual angle selection. The time to perform a beam direction search was approximately 2 min for the coplanar and 12 min for the non-coplanar beam space. The angles obtained for the prostate case compared well with reports in the literature. For the brain case, the mean dose to the right and left optic nerves was reduced by 12% and 50%, respectively, whilst the target dose uniformity was improved. For the sinus case, the mean doses to the right and left parotid glands were reduced by 54% and 46%, respectively, to the right and left optic nerves by 37% and 62%, respectively, and to the optic chiasm by 39%, whilst the target dose uniformity was also improved. For the clinical cases the plans based on optimized beam directions were simpler and resulted in better sparing of critical structures compared with plans based on manual angle selection. The approach provides a practical alternative to elaborate and time consuming beam angle optimization schemes and is suitable for routine clinical usage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.