The aim of this study was to determine the accuracy and interrater reliability of (1) point-of-care ultrasound (POCUS) image interpretation for identification of intussusception and (2) reliability of secondary signs associated with intussusception among experts compared with novice POCUS reviewers. Methods:We conducted a planned secondary analysis of a prospective, convenience sample of children aged 3 months to 6 years who were evaluated with POCUS for intussusception across 17 international pediatric emergency departments between October 2018 and December 2020. A random sample of 100 POCUS examinations was reviewed by novice and expert POCUS reviewers. The primary outcome was identification of the presence or absence of intussusception. Secondary outcomes included intussusception size and the presence of trapped free fluid or echogenic foci. Accuracy was summarized using sensitivity and specificity, which were estimated via generalized mixed effects logistic regression. Interrater reliability was summarized via Light's κ statistics with bootstrapped standard errors (SEs). Accuracy and reliability of expert and novice POCUS reviewers were compared.Results: Eighteen expert and 16 novice POCUS reviewers completed the reviews. The average expert sensitivity was 94.5% (95% confidence interval [CI], 88.6-97.5), and the specificity was 94.3% (95% CI, 90.3-96.7), significantly higher than the average novice sensitivity of 84.7% (95% CI, 74.3-91.4) and specificity of 80.4% (95% CI, 72.4, 86.7). κ was significantly greater for expert (0.679, SE 0.039) compared with novice POCUS reviewers (0.424, SE 0.044; difference 0.256, SE 0.033). For our secondary outcome measure of intussusception size, κ was significantly greater for experts (0.661, SE 0.038) compared with novices (0.397, SE 0.041; difference 0.264, SE 0.029). Interrater reliability was weak for expert and minimal for novice reviewers regarding the detection of trapped free fluid and echogenic foci.Conclusions: Expert POCUS reviewers demonstrate high accuracy and moderate interrater reliability when identifying intussusception via image interpretation and perform better than novice reviewers.
The aim of the study is to analyze whether repeat testing is necessary in healthy children presenting to a pediatric emergency department (ED) who are found to have hyperkalemia on a hemolyzed specimen. Methods:A 5-year retrospective analysis of pediatric ED patients found to have elevated potassium values on laboratory testing of a sample reported to be hemolyzed. All patients aged 0 to 17 years who had an elevated potassium level after an intravenous draw resulted from a serum sample that was reported as hemolyzed during an ED visit were included in the study.Results: One hundred eighty-seven patients with some degree of both hemolysis and hyperkalemia were included in the final analysis. The median age was 1.9 years of age. The most common race among all patients was White, followed by African American, and Asian. One hundred forty-five children had repeat sampling for hemolyzed hyperkalemia, 142 children, 97.9% (95% confidence interval, 95.6%-100%) had a normal potassium on repeat and 3 children, 2.1% (95% confidence interval, 0.0%-4.4%) had true hyperkalemia. The frequency of true hyperkalemia in our study population was 2% (3/145). All 3 of these patients had underlying conditions that would appropriately have raised clinician suspicion for hyperkalemia.Conclusions: It may be unnecessary to obtain repeat samples to confirm normal potassium in a hemolyzed sample with normal blood urea nitrogen and creatinine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.