Introduction and hypothesisThe aim of this study was to evaluate the long-term effect of thermoablative fractional CO2 laser (TACO2L) as an alternative treatment for early stages of stress urinary incontinence (SUI) in postmenopausal women with genitourinary syndrome of menopause.MethodsA total of 161 postmenopausal patients (age 53.38 ± 5.1 years, range 45–65 years) with a clinical diagnosis of mild SUI were prospectively enrolled in the study. Patients received one treatment with TACO2L every 30–45 days, each treatment comprising four sessions, followed in all patients by a yearly treatment session at 12, 24 and 36 months. SUI was evaluated using the International Continence Society 1-h pad test and the International Consultation on Incontinence Questionnaire-Urinary Incontinence Short Form (ICIQ-UI SF) before and after TACO2L treatment.ResultsTACO2L treatment was associated with a significant improvement in ICIQ-UI SF scores and 1-h pad weight test at 12 months (both p < 0.001), 24 months (both p < 0.001) and 36 months (both p < 0.001). Improvements were maintained for up to 36 months without the need for any further intervention. The results were confirmed by significant histological changes related to trophic restoration of the vagina, responsible for extrinsic and intrinsic mechanisms involved in urinary continence.ConclusionsOur results suggest that TACO2L is an efficient and safe novel treatment strategy in patients with mild SUI. Further investigation to confirm the long-term results presented here is still warranted.
OBJECTIVE:Neauvia Stimulate is biocompatible, injectable hyaluronic acid (HA) filler (26 mg/ml) PEG cross-linked with 1% of calcium hydroxyapatite (CaHA) for facial soft-tissue augmentation that provides volume to tissues, followed by process of neocollagenesis for improving skin quality.AIM:The aim of the present study is to evaluate the biosafety of the product (Lot. 160517-26-1/2 PEG) on human keratinocytes cultured in vitro.MATERIAL AND METHODS:The experimental model proposed, despite being an in vitro system, allows the derivation of useful information to predict the possible activity of the product in further in vivo application. Human keratinocytes (HaCaT cells) were treated with the product for 24h at increasing concentrations of product respect to control (untreated cells).RESULTS:The biosafety of the product to be tested has been evaluated performing different methods: MTT test, NRU test, Kenacid Blue assay. Moreover, any possible effect on the structure, morphology, and viability of cells has been evaluated.CONCLUSION:In conclusion, the results obtained by the different methods show that the product Neauvia Stimulate® does not cause any cytotoxic effect and does not affect the correct structure and morphology of cells cultures.
Background and Objectives: Urinary incontinence is the accidental loss of urine that can occur at any age, especially among women over 50; however, its prevalence is increasing. This study aimed to assess the efficacy and safety of a device that uses Top Flat Magnetic Stimulation for the management of women with mixed urinary incontinence. Materials and Methods: A total of 50 female patients underwent a total of six treatment sessions performed twice a week for three consecutive weeks, for 28 min. Three questionnaires were used for the evaluation of the urinary improvements: Urinary Incontinence Short Form (ICIQ-UI-SF), Incontinence Questionnaire Overactive Bladder Module (ICIQ-OAB), and Incontinence Impact Questionnaire-Short Form (IIQ-7). The questionnaires were compiled immediately before each treatment, within the treatment period (until the sixth treatment session), and up to 3 months of follow-up. Results: Improvement in quality of life is observed according to the results of the questionnaire, already after six sessions and at three months follow-up. ICIQ-UI-SF’s average score at baseline was 20.2 (±1.1), and it significantly declined (p < 0.01) to 1.8 (±2.4) after six sessions and to 4.8 (±2.8) at 3 months follow-up; ICIQ-OAB’s average score significantly decreased (p < 0.01) from 10.4 (±3.2) at baseline to 1.4 (±0.8) after six sessions and 2.3 (±1.6) at 3 months follow-up. IIQ-7’s average score significantly decreased (p < 0.01) from 20.2 (±1.7) at baseline to 0.4 (±0.5) after six sessions and to 4.7 (±2.8) at 3 months follow-up. Conclusions: Our results suggest that Top Flat Magnetic Stimulation technology can reduce mixed urinary incontinence symptoms for all women examined, leading to an improvement in the patient quality of life and patient awareness of their pelvic floor area with good results.
OBJECTIVE:To describe the benefits and safety of using Carbon Dioxide Laser in multi-pulse modalities when performing labiaplasty and anatomical variants approach for functional and cosmetic indications.DESIGN:This is a prospective, descriptive case series study.SETTING:Private Practice Quirofano Calculaser Megacentro Pinares Pereira Colombia.POPULATION:One Hundred and twelve women seeking labia minora labiaplasty for functional and cosmetic reasons were enrolled in the study protocol from June 2013 to June 2016. Labia minora labioplasty and anatomical variants approach were performed with Carbon Dioxide laser Multi-pulse modalities DEKA M.EL.A Florence ItalyMAIN OUTCOME MEASURES:Good Cosmetic results, functional and sexuality improvementRESULTS:Dramatic changes in the VAS and VSQ were detected after the surgical procedure. All the participants reported a high degree of satisfaction, felt more confident with their partners during sexual encounters, and the procedure was well tolerated.CONCLUSION:Laser Carbon Dioxide Laser with a new pulse profile and shape seems to be a safe and precise surgical tool to perform this type of procedures, optimal biophysical and bio stimulative laser-tissue interactions allow delicate vulvar tissues to shorten downtime.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.