Hyperammonemic encephalopathy is an uncommon, potentially lethal adverse effect of 5-fluorouracil (5-FU). Being one of the most common and versatile chemotherapy agents, it is important to understand this important side effect of 5FU. There is paucity of data in this subject. Here, we report a case of 5FU-induced encephalopathy in a patient on induction chemotherapy for head and neck cancer. In this case report, the clinical presentation, diagnosis, and management of 5FU-induced encephalopathy is reported.
Introduction: Breast cancer treated with adjuvant hypofractionation radiotherapy with two different techniques, i.e., volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) and their effects in terms of loco-regional control and adverse effects in terms of cutaneous, pulmonary, and cardiac outcomes are compared.
Materials and methods: This is a prospective non-randomized observational study. VMAT and IMRT plan for 30 breast cancer patients who were supposed to receive adjuvant radiotherapy were prepared using a hypofractionation schedule. The plans were dosimetrically evaluated.
Objective: Dosimetric comparative analysis of IMRT and VMAT in hypofractionated radiotherapy in breast cancer is done and tested whether VMAT has a dosimetric advantage over IMRT. These patients were recruited for a clinical assessment of toxicities. They were followed up for at least three months.
Result: On dosimetric analysis, planning target volume (PTV) coverage (PTV_
V95
) of both VMAT (96.41 ± 1.31) and IMRT (96.63 ± 1.56) were similar with significantly lower monitor units required with VMAT plans (1,084.36 ± 270.82 vs 1,181.55 ± 244.50, p = 0.043). Clinically, all patients tolerated hypofractionation through VMAT (n = 8) and IMRT (n = 8) satisfactorily in the short term. No cardiotoxicity or appreciable falls in pulmonary function test parameters were observed. Acute radiation dermatitis poses challenges similar to standard fractionation or any other delivery technique.
Conclusion: PVT dose, homogeneity, and conformity indices were similar in both VMAT and IMRT groups. In VMAT, there was high-dose sparing of some critical organs like the heart and lungs at the cost of the low-dose baths to these organs. Increased risk of secondary cancer will require a decade-long follow-up study to indict the VMAT technique. As we move toward precision in oncology, “one-size-fits-all” can never be an acceptable dictum. Each patient is unique and therefore we must offer, and the patient must “choose wisely.”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.