Background The Ganz’ periacetabular osteotomy (PAO) consists of four technically challenging osteotomies (OT), namely, supraacetabular (saOT), pubic (pOT), ischial (iOT), and retroacetabular OT (raOT). Purpose We performed a proof of concept study to test (1) the feasibility of augmented reality (AR) guidance for PAO, (2) precision of the OTs guided by AR compared to the freehand technique performed by an experienced PAO surgeon, and (3) the effect of AR on performance depending on experience. Methods A 3D preoperative plan of a PAO was created from segmented computed tomography (CT) data of an anatomic plastic pelvis model (PPM). The plan was then embedded in a software application for an AR head-mounted device. Soft tissue coverage was imitated using foam rubber. The 3D plan was then registered onto the PPM using an anatomical landmark registration. Two surgeons (one experienced and one novice PAO surgeon) each performed 15 freehand (FH) and 15 AR-guided PAOs. The starting point distances and angulation between the planned and executed OT planes for the FH and the AR-guided PAOs were compared in post-intervention CTs. Results AR guidance did not affect the performance of the expert surgeon in terms of the mean differences between the planned and executed starting points, but the raOT angle was more accurate as compared to FH PAO (p = 0.0027). AR guidance increased the accuracy of the performance of the novice surgeon for iOT (p = 0.03). An intraarticular osteotomy performed by the novice surgeon with the FH technique could be observed only once. Conclusion AR guidance of osteotomies for PAOs is feasible and seems to increase accuracy. The effect is more accentuated for less-experienced surgeons. Clinical relevance This is the first proof of concept study documenting the feasibility of AR guidance for PAO. Based on these findings, further studies are essential for elaborating on the potential merits of AR guidance to increase the accuracy of complex surgical procedures.
Background: Left ventricular non-compaction cardiomyopathy (LVNC) features extensive trabeculations. Involvement of the right ventricle (RV) has been reported; however, distinction from normal RV trabeculation is difficult. This study aimed at assessing RV morphology and function in LVNC by cardiac magnetic resonance (CMR) and transthoracic echocardiography (TTE). Methods: Dimensional and functional parameters were assessed according to guidelines. Novel CMR parameters were RV end-diastolic (ED) trabeculated area, RV ED trabeculated volume, and RV ED non-compacted to compacted (NC/N) ratio in short axis (SAX) as well as in four-chamber view (4CH). Results: Twenty patients with LVNC and 20 controls were included. RV size and function were comparable in LVNC and controls and exhibited a good correlation between TTE and CMR. Although RV trabeculated area, RV trabeculated volume, and RV ED NC/C ratio in SAX as well as in 4CH were larger in LVNC, there was a major overlap with values in controls. RV ED NC/C ratio in SAX correlated with LV ED NC/C ratio (not in 4CH). Quantitative assessment of RV non-compaction was not feasible in TTE. Conclusions: Right ventricle size and function in LVNC can be measured by CMR and TTE, while RV trabeculation can only be quantified by CMR. RV myocardium displays more trabeculations in LVNC; however, overlap with normal individuals is extensive, not allowing separation of patients with LVNC from controls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.