Calibration model selection is required for all quantitative methods in toxicology and more broadly in bioanalysis. This typically involves selecting the equation order (quadratic or linear) and weighting factor correctly modelizing the data. A mis-selection of the calibration model will generate lower quality control (QC) accuracy, with an error up to 154%. Unfortunately, simple tools to perform this selection and tests to validate the resulting model are lacking. We present a stepwise, analyst-independent scheme for selection and validation of calibration models. The success rate of this scheme is on average 40% higher than a traditional "fit and check the QCs accuracy" method of selecting the calibration model. Moreover, the process was completely automated through a script (available in Supplemental Data 3) running in RStudio (free, open-source software). The need for weighting was assessed through an F-test using the variances of the upper limit of quantification and lower limit of quantification replicate measurements. When weighting was required, the choice between 1/x and 1/x2 was determined by calculating which option generated the smallest spread of weighted normalized variances. Finally, model order was selected through a partial F-test. The chosen calibration model was validated through Cramer-von Mises or Kolmogorov-Smirnov normality testing of the standardized residuals. Performance of the different tests was assessed using 50 simulated data sets per possible calibration model (e.g., linear-no weight, quadratic-no weight, linear-1/x, etc.). This first of two papers describes the tests, procedures and outcomes of the developed procedure using real LC-MS-MS results for the quantification of cocaine and naltrexone.
In the first part of this paper (I-Description and application), an automated, stepwise and analyst-independent process for the selection and validation of calibration models was put forward and applied to two model analytes. This second part presents the mathematical reasoning and experimental work underlying the selection of the different components of this procedure. Different replicate analysis designs (intra/inter-day and intra/inter-extraction) were tested and their impact on test results was evaluated. For most methods, the use of intra-day/intra-extraction measurement replicates is recommended due to its decreased variability. This process should be repeated three times during the validation process in order to assess the time stability of the underlying model. Strategies for identification of heteroscedasticity and their potential weaknesses were examined and a unilateral F-test using the lower limit of quantification and upper limit of quantification replicates was chosen. Three different options for model selection were examined and tested: ANOVA lack-of-fit (LOF), partial F-test and significance of the second-order term. Examination of mathematical assumptions for each test and LC-MS-MS experimental results lead to selection of the partial F-test as being the most suitable. The advantages and drawbacks of ANOVA-LOF, examination of the standardized residuals graph and residuals normality testing (Kolmogorov-Smirnov or Cramer-Von Mises) for validation of the calibration model were examined with the last option proving the best in light of its robustness and accuracy. Choosing the correct calibration model improves QC accuracy, and simulations have shown that this automated scheme has a much better performance than a more traditional method of fitting with increasingly complex models until QC accuracies pass below a threshold.
Cyanide is a powerful chemical asphyxiant found in some forensic cases following voluntary (suicide) or involuntary ingestion (fire, accidental exposure). A quantification method for cyanide that is specifically suited to post-mortem forensic purposes was developed. Determination was performed by headspace gas chromatography coupled to mass spectrometry using a GS-GASPRO column on an HP-6890 gas chromatograph with an HP-5973N mass detector. The biological sample was treated with an internal standard, frozen, glacial acetic acid was added and the sample was then incubated at 60°C for 15 min. The headspace was sampled with a disposable syringe, and analyzed to quantify hydrogen cyanide. Isotopically labeled cyanide ((13)C(15)N) was used as the internal standard to minimize matrix effect and sampling error. The method produced an extended linear dynamic range (0.07-50 μg/mL), and a method detection limit of 0.02 μg/mL. Identical calibration curves were obtained when blood, gastric contents and aqueous solutions were used as the calibration standard matrix. This method was also successful in quantitating cyanide in gastric contents, one of the most variable biological fluids. The method has been validated and is being used for current forensic cases such as fire victims and suicides.
Calculating the confidence interval is a common procedure in data analysis and is readily obtained from normally distributed populations with the familiar [Formula: see text] formula. However, when working with non-normally distributed data, determining the confidence interval is not as obvious. For this type of data, there are fewer references in the literature, and they are much less accessible. We describe, in simple language, the percentile and bias-corrected and accelerated variations of the bootstrap method to calculate confidence intervals. This method can be applied to a wide variety of parameters (mean, median, slope of a calibration curve, etc.) and is appropriate for normal and non-normal data sets. As a worked example, the confidence interval around the median concentration of cocaine in femoral blood is calculated using bootstrap techniques. The median of the non-toxic concentrations was 46.7 ng/mL with a 95% confidence interval of 23.9-85.8 ng/mL in the non-normally distributed set of 45 postmortem cases. This method should be used to lead to more statistically sound and accurate confidence intervals for non-normally distributed populations, such as reference values of therapeutic and toxic drug concentration, as well as situations of truncated concentration values near the limit of quantification or cutoff of a method.
In the last two decades, a large increase in opioid overdose death rates has been recorded in North America. This phenomenon, related to the misuse of prescription opioids, has been dubbed an "opioids crisis". Recent years have seen the entrance of novel synthetic opioids (NSO) on the market, compounding the fatal intoxications issue. This brings several challenges for forensic toxicology laboratories: an increased number of cases, a large number of novel structurally similar compounds to include in screening analytical methods, the low concentration of drugs in biological fluids, and the challenging interpretation in the absence of sufficient literature. Three cases of fatal intoxication highlighting those challenges are presented, complete with post-mortem concentrations in cardiac blood, femoral blood and urine. Toxicological screening and quantitative analyses were performed on the biological specimens. In the first and second cases, furanylfentanyl, U-47700 and 4-anilino-N-phenethylpiperidine (4-ANPP) were detected at similar concentrations in cardiac blood. In the third case, a total of seventeen different NSO were detected. All intoxications showed a combination of NSO and other drugs. These three cases appear to be the harbinger of an increased NSO prevalence in the province of Québec, Canada.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.