Background
The robotic Heller‐Dor (RHD) procedure for oesophageal achalasia (EA) is safe and effective. We aim to evaluate the intraoperative use of fluorescence imaging, as an alternative means to intraoperative endoscopy, to assess myotomy at the end of the procedure.
Methods
Thirty‐four patients affected with EA underwent RHD. The myotomy was assessed intraoperatively by endoscopy in group A (17 patients), and by fluorescence imaging in group B (17 patients). Perioperative and long‐term results were compared.
Results
In group A, one mucosal tear was identified during intraoperative endoscopy. In group B, indocyanine green (ICG) helped identify residual muscle fibres in three cases. No perforation of the oesophageal mucosa occurred in group B.
Conclusions
Fluorescence‐imaging improved the identification of residual muscle fibres and made it possible to verify the integrity of the mucosa without the use of intraoperative endoscopy. A significant reduction in operative times has been related to the use of this technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.