The aim of this work was to study the rheological, thermal and some other physical-chemical properties of selected honeys produced in the Northeast of Brazil. Two samples were produced by native “Jandaira” bees (Melipona subnitida) and ten other samples by Africanized bees (Apis mellifera). The samples were analyzed for pH, water activity (aW), soluble solids and water content. Viscosity flow curves were obtained using a rheometer (25ºC, 0-100s-1). Thermal analyses were performed on a differential scanning calorimeter, with heating rate of 10ºC/min (-100 to 100ºC). The water content and the pH of the honey samples varied from 17.2 to 27.9% and from 3.2 to 4.2, respectively, and, the aW of the samples varied from 0.57 to 0.74. Two samples were out of specification with respect to water content, according to Brazilian laws. In relation to rheology, all honey samples showed Newtonian behaviour with no thixotropy or dilatancy. The viscosity varied as an exponential function of the water content. The highest viscosity was obtained for the sample with lower values of water content and aW. Thermograms showed a glass transition (Tg) occurring between -52.4 and -42.6ºC, in the samples produced by Apis mellifera and -67.6 and -57.0ºC for the other samples. A linear relationship was obtained between Tg and water content. In conclusion, the honey viscosity depended on the water content of the product. The higher the water value and therefore the greater the aw, the lower viscosity and Tg of the samples.
The aim of this work was to study the rheological, thermal and some other physical-chemical properties of selected honeys produced in the Northeast of Brazil. Two samples were produced by native "Jandaira" bees (Melipona subnitida) and ten other samples, by Africanized bees (Apis mellifera). The samples were analyzed for pH, water activity (aw), soluble solids and water content. Viscosity flow curves were obtained using a rheometer (25ºC, 0-100s −1 ). Thermal analyses were performed on a differential scanning calorimeter, with heating rate of 10ºC/min (-100 to 100ºC). The water content and the pH of the honey samples varied from 17.2 to 27.9% and from 3.2 to 4.2, respectively, and, the aw of the samples varied from 0.57 to 0.74. Two samples were out of specification with respect to water content, according to Brazilian laws. In relation to rheology, all honey samples showed Newtonian behaviour with no thixotropy or dilatancy. The viscosity varied as an exponential function of the water content. The highest viscosity was obtained for the sample with lower values of water content and aw. Thermograms showed a glass transition (Tg) occurring between -52.4 and -42.6ºC, in the samples produced by Apis mellifera and -67.6 and -57.0ºC for the other samples. A linear relationship was obtained between Tg and water content. In conclusion, the honey viscosity depended on the water content of the product. The higher the water value and therefore the greater the aw, the lower viscosity and Tg of the samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.