Tremors are common disorders characterized by an involuntary and relatively rhythmic oscillation that can occur in any part of the body and may be physiological or associated with some pathological condition. It is known that the mass loading can change the power spectral distribution of the tremor. Nowadays, many instruments have been used in the evaluation of tremors with bult-in inertial sensors, such as smartphones and wearables, which can significantly differ in the device mass. The aim of this study was to compare the quantification of hand tremor using Fourier spectral techniques obtained from readings of accelerometers built-in a lightweight handheld device and a commercial smartphone in healthy young subjects. We recruited 28 healthy right-handed subjects with ages ranging from 18 to 40 years. We tested hand tremors at rest and postural conditions using lightweight wearable device (5.7 g) and smartphone (169 g). Comparing both devices at resting tremor, we found with smartphone the power distribution of peak ranging 5 and 12 Hz in both hands. With wearable, the result was similar but less evident. When comparing both devices in postural tremor, there were significant differences in both frequency ranges in peak frequency and peak amplitude in both hands. Our main findings show that in resting condition the hand tremor spectrum had a higher peak amplitude in the 5–12 Hz range when the tremor was recorded with smartphones, and in postural condition there was a significantly (p < 0.05) higher peak power spectrum and peak frequency in the dominant hand tremors recorded with smartphones compared to those obtained with lightweight wearable device. Devices having different masses can alter the features of the hand tremor spectrum and their mutual comparisons can be prejudiced.
Falls represent a public health issue around the world and prevention is an important part of the politics of many countries. The standard method of evaluating balance is posturography using a force platform, which has high financial costs. Other instruments, such as portable devices and smartphones, have been evaluated as low-cost alternatives to the screening of balance control. Although smartphones and wearables have different sizes, shapes, and weights, they have been systematically validated for static balance control tasks. Different studies have applied different experimental configurations to validate the inertial measurements obtained by these devices. We aim to evaluate the concurrent validity of a smartphone and a portable device for the evaluation of static balance control in the same group of participants. Twenty-six healthy and young subjects comprised the sample. The validity for static balance control evaluation of built-in accelerometers inside portable smartphone and wearable devices was tested considering force platform recordings as a gold standard for comparisons. A linear correlation (r) between the quantitative variables obtained from the inertial sensors and the force platform was used as an indicator of the concurrent validity. Reliability of the measures was calculated using Intraclass correlation in a subsample (n = 14). Smartphones had 11 out of 12 variables with significant moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables in open eyes, closed eyes, and unipedal conditions, while wearable devices had 8 out of 12 variables with moderate to very high correlation (r > 0.5, p < 0.05) with force platform variables under the same task conditions. Significant reliabilities were found in closed eye conditions for smartphones and wearables. The smartphone and wearable devices had concurrent validity for the static balance evaluation and the smartphone had better validity results than the wearables for the static balance evaluation.
(1) Background: Tropical spastic paraparesis (TSP/HAM) associated with the T cell lymphotropic virus in type I humans (HTLV-1) is a slow, chronic, and progressive disease that causes balance changes. TSP/HAM diagnosis can be classified as probable, possible, and definite. We compared the static balance control of HTLV-1-infected patients with different TSP/HAM diagnosis. (2) Methods: Our sample consisted of 13 participants infected with HTLV-1 and 16 healthy participants. The center of pressure was recorded using a force platform with open and closed eyes. We divided the recordings into three intervals, period T1 (corresponds to the first 10 s); period T2 (from 10 to 45 s); period T3 (from 45 to 55 s). (3) Results: Eight participants infected with HTLV-1 were classified as probable TSP/HAM and five participants infected with HTLV-1 were classified as definite TSP/HAM. There was a significant increase in postural instability in patients with definite PET/MAH considering the structural and global variables of body sway compared to the control and the probable TSP/HAM. (4) Conclusions: We concluded that the severity of balance is directly related to the degree of signs and symptoms of TSP/HAM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.