A standardized protocol is a valuable and effective tool for improving the quality of histopathology reporting. Its implementation is associated with more precise specimen evaluation, higher numbers of harvested lymph nodes, and improved completeness of histopathology reports.
Aims.To determine the frequency of pregnancy terminations due to prenatal congenital heart defect (CHD) and assess the agreement fetal echocardiography (FECHO) and autopsy findings. Methods. The data were retrospectively assessed between 2008 and 2017 in a population of 116 698 live births. The correlations between the FECHO and autopsy findings were classified into five levels of agreement: complete, partial, altered diagnosis, disagreement, and unfeasible autopsy. Results. Totally, 293 CHDs were identified and 49% of families (143/293) decided to terminate the pregnancy. In 1% (2/143) of cases, the autopsy could not be performed, for the other 99% (141/143), the pathologist confirmed the presence of CHDs. Complete agreement between FECHO and autopsy was achieved in 85% (122/143). In 10% (14/143) of cases, the pathologist found minor findings, which were not described in the FECHO. In 4% (5/143) of cases, the pathologist changed the main diagnosis. Conclusion. Altogether, the results indicated that FECHO is a highly sensitive method for the prenatal detection of CHD but is incapable of detecting the complete spectrum of cardiac defects. Autopsies verified the diagnosis, confirmed the overall impairment in the fetus, and provided data for further counselling of the affected family.
The incidence of colorectal carcinoma is still growing in the Czech Republic and also all around the world. With success of oncological treatment is also growing a number of potential patients with liver metastases, who can profit from surgical therapy. The aim of this study was to confirm on porcine models that this method by using new surgical device is effective and safe for patients who have to undergo liver resection. The primary hypothesis of the study was to evaluate whether this new device is able to consistently produce homogeneous and predictable areas of coagulation necrosis without the Pringle maneuver of vascular inflow occlusion. The secondary hypothesis of the study was to compare the standard linear radiofrequency device and a new semi-spherical bipolar device for liver ablation and resection in a hepatic porcine model. Twelve pigs were randomly divided into two groups. Each pig underwent liver resection from both liver lobes in the marginal, thinner part of liver parenchyma. The pigs in first group were operated with standard using device and in the second group we used new developed semi-spherical device. We followed blood count in 0(th), 14(th) and 30(th) day from operation. 14(th) day from resection pigs underwent diagnostic laparoscopy to evaluate of their state, and 30(th) day after operation were all pigs euthanized and subjected to histopathological examination. Histopathological evaluation of thermal changes at the resection margin showed strong thermal alteration in both groups. Statistical analysis of collected dates did not prove any significant (p < 0.05) differences between standard using device and our new surgical tool. We proved safety of new designed semi-spherical surgical. This device can offer the possibility of shortening the ablation time and operating time, which is benefit for patients undergoing the liver resection.
The aim of this study is to inform about the development of a new semispherical surgical instrument for the bipolar multielectrode radiofrequency liver ablation. Present tools are universal; however they have several disadvantages such as ablation of healthy tissue, numerous needle punctures, and, therefore, longer operating procedure. Our newly designed and tested semispherical surgical tool can solve some of these disadvantages. By conducting an in vivo study on a set of 12 pigs, randomly divided into two groups, we have compared efficiency of the newly developed instrument with the commonly used device. Statistical analysis showed that there were no significant differences between the groups. On average, the tested instrument RONJA had shorter ablation time in both liver lobes and reduced the total operating time. The depth of the thermal alteration was on average 4 mm larger using the newly tested instrument. The new radiofrequency method described in this study could be used in open liver surgery for the treatment of small liver malignancies (up to 2 cm) in a single application with the aim of saving healthy liver parenchyma. Further experimental studies are needed to confirm these results before clinical application of the method in the treatment of human liver malignancies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.