During the cementation of ceramic veneers the polymerization of resin cements may be jeopardized if the ceramics attenuate the irradiance of the light-curing device. The aim of this study was to evaluate the effect of different types and thicknesses of ceramic veneers on the degree of conversion of a light-cured resin-based cement (RelyX Veneer). The cement was light-cured after interposing ceramic veneers [IPS InLine, IPS Empress Esthetic, IPS e.max LT (low translucency) and IPS e.max HT (high translucency) - Ivoclar Vivadent] of four thicknesses (0.5 mm, 1.0 mm, 1.5 mm and 2.0 mm). As control, the cement was light-cured without interposition of ceramics. The degree of conversion was evaluated by FTIR spectroscopy (n=5). Data were analyzed with one-way ANOVA and Tukey's test (α=0.05). Significant differences were observed among groups (p<0.001). The degree of conversion was similar to the control for all light-cured groups with interposition of ceramics of 0.5 mm and 1.0 mm (p>0.05). Among 1.5-mm-thick veneers, IPS e.max LT was the only one that showed different results from the control (p<0.05). At the thickness of 2.0 mm, only the IPS e.max LT and HT veneers were able to produce cements with degrees of conversion similar to the control (p>0.05). The degree of conversion of the evaluated light-cured resin cement depends on the thickness and type of ceramics employed when veneers thicker than 1.5 mm are cemented.
SUMMARY Objective: The objective of this study was to evaluate the in vivo effectiveness of air spray to reduce pulp temperature rise during exposure of intact premolars to light emitted by a high-power LED light-curing unit (LCU). Methods and Materials: After local Ethics Committee approval (#255945), intact, upper first premolars requiring extraction for orthodontic reasons from five volunteers received infiltrative and intraligamental anesthesia. The teeth (n=9) were isolated using rubber dam, and a minute pulp exposure was attained. The sterile probe from a wireless, NIST-traceable, temperature acquisition system was inserted directly into the coronal pulp chamber. Real-time pulp temperature (PT) (°C) was continuously monitored, while the buccal surface was exposed to a polywave LED LCU (Bluephase 20i, Ivoclar Vivadent) for 30 seconds with simultaneous application of a lingually directed air spray (30s-H/AIR) or without (30s-H), with a seven-minute span between each exposure. Peak PT values were subjected to one-way, repeated-measures analysis of variance, and PT change from baseline (ΔT) during exposure was subjected to paired Student's t-test (α=0.05). Results: Peak PT values of the 30s-H group were significantly higher than those of 30s-H/AIR group and those from baseline temperature (p<0.001), whereas peak PT values in the 30s-H/AIR group were significantly lower than the baseline temperature (p=0.003). The 30s-H/AIR group showed significantly lower ΔT values than did the 30s-H group (p<0.001). Conclusion: Applying air flow simultaneously with LED exposure prevents in vivo pulp temperature rise.
Objectives: To measure and compare in vivo and in vitro pulp temperature (PT) increase (ΔTEMP) over baseline, physiologic temperature using the same intact upper premolars exposed to the same Polywave ® LED curing light. Methodology: After local Ethics Committee approval (#255,945), local anesthesia, rubber dam isolation, small occlusal preparations/minute pulp exposure (n=15) were performed in teeth requiring extraction for orthodontic reasons. A sterile probe of a temperature measurement system (Temperature Data Acquisition, Physitemp) was placed within the pulp chamber and the buccal surface was sequentially exposed to a LED LCU (Bluephase 20i, Ivoclar Vivadent) using the following exposure modes: 10-s low or high, 5-s Turbo, and 60-s high. Afterwards, the teeth were extracted and K-type thermocouples were placed within the pulp chamber through the original access. The teeth were attached to an assembly simulating the in vivo environment, being similarly exposed while real-time temperature (°C) was recorded. ΔTEMP values and time for temperature to reach maximum (ΔTIME) were subjected to two-way ANOVA and Bonferroni's post-hoc tests (pre-set alpha 0.05). Results: Higher ΔTEMP was observed in vitro than in vivo . No significant difference in ΔTIME was observed between test conditions. A significant, positive relationship was observed between radiant exposure and ΔTEMP for both conditions ( in vivo : r2=0.917; p<0.001; in vitro : r2=0.919; p<0.001). Conclusion: Although the in vitro model overestimated in vivo PT increase, in vitro PT rise was close to in vivo values for clinically relevant exposure modes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.