Elephantiasis nostras verrucosa is a rare disorder that results from chronic obstructive lymphedema. It is characterized clinically by deforming, nonpitting edema; malodorous hyperkeratosis with generalized lichenification; cobblestoned papules; and verrucous changes, that often result in extreme enlargement of the involved body part. Although elephantiasis nostras verrucosa is striking in clinical appearance, biopsy reveals only moderately abnormal findings: pseudoepitheliomatous hyperplasia with dilated lymphatic spaces in the dermis, accompanied by chronic inflammation and fibroblast proliferation. The term elephantiasis nostras (nostras means "from our region") has traditionally been used to differentiate temperate zone disease from the classic disease process, elephantiasis tropica, which is defined by chronic filarial lymphatic obstruction caused by Wuchereria bancrofti, Wuchereria malayi, or Wuchereria pacifica. We present a case report of elephantiasis nostras verrucosa arising as a result of lymphedema praecox.
Background
The Evans osteotomy is a widely used procedure for the correction of adult and pediatric flexible flatfoot deformity. Locking plates are commonly used to stabilize the osteotomy and the allograft. However, there have been incidences of soft-tissue irritation caused by the hardware, requiring subsequent hardware removal. Therefore, we sought to review whether age, sex, or laterality of the procedure had any correlation with the rate of hardware removal.
Methods
A retrospective review was performed of 47 consecutive patients who underwent an Evans calcaneal osteotomy between October 1, 2013, and October 1, 2016. Data were collected and analyzed based on age, sex, laterality, and the need for hardware removal.
Results
All of the 47 patients met the inclusion criteria. Seventy procedures were performed, and hardware removal was required in 16 patients and 21 feet (30%). The only statistically significant finding was that 11 females and only five males required either unilateral or bilateral hardware removal (P = .039). All 16 patients reported complete pain relief after hardware removal.
Conclusions
Females are twice as likely as males to develop symptoms after locking plate application over an Evans osteotomy and may require hardware removal. Despite the low-profile nature of the locking plate to fixate the Evans osteotomy, the hardware can be a source of significant pain. Patients, especially females, should be cautioned about potential hardware-related pain and a possible follow-up procedure to remove the hardware.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.