In a multicenter study involving three reference centers for mycobacteria, the rate of recovery of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens was determined by using the Mycobacteria Growth Indicator Tube (MGIT). These parameters were compared to those assessed by the radiometric BACTEC 460 TB system and by cultivation on solid media. Clinical specimens (n ؍ 1,500) were pretreated with N-acetyl-L-cysteine (NALC)-NaOH. The contamination rates for MGITs were 2.0% (center 1), 13.8% (center 2), and 6.1% (center 3). A total of 180 mycobacterial isolates were detected (M. tuberculosis complex, n ؍ 113; nontuberculous mycobacteria [NTM], n ؍ 67). When using a combination of liquid and solid media (the current "gold standard" for culture), MGIT plus solid media detected 156 (86.7%) of the isolates, whereas BACTEC plus solid media recovered 168 (93.3%) of all AFB. Between these two gold standards there was no statistically significant difference (P > 0.05). The combination of MGIT plus BACTEC detected 171 (95.0%) of all isolates (compared with MGIT plus solid media, P < 0.01; compared with BACTEC plus solid media, P > 0.05). Considering the efficacies of the different media separately, MGIT was superior to solid media (although not significantly; P > 0.05) in detecting AFB but was inferior to the BACTEC system (P < 0.01). The mean time to the detection of M. tuberculosis complex was 9.9 days with MGIT, 9.7 days with BACTEC, and 20.2 days with solid media. NTM needed, on average, 11.9, 13.0, and 22.2 days to appear by the three methods, respectively. In conclusion, MGIT proved to be a valuable alternative to the radiometric cultivation system.
A total of 938 respiratory specimens (633 sputa, 249 bronchial and tracheal aspirates, and 56 bronchoalveolar lavages) from 589 patients were tested for direct detection of Mycobacterium tuberculosis complex by the Gen-Probe amplified Mycobacterium tuberculosis direct test (MTD), and the results were compared with those of the conventional methods of fluorescence microscopy and cultivation (solid and radiometric media). One series of specimens (n = 515) was decontaminated with N-acetyl-L-cysteine (NALC)-NaOH; the other one (n = 423) was decontaminated with sodium dodecyl (lauryl) sulfate (SDS)-NaOH. Of the specimens decontaminated with NALC, 39 were MTD and culture positive, 455 were MTD and culture negative, 18 were MTD positive and culture negative, and 3 were MTD negative and culture positive, indicating a sensitivity of 92.9% and a specificity of 96.2% for the MTD. Of the specimens decontaminated with SDS, 35 were MTD and culture positive, 372 were MTD and culture negative, 15 were MTD positive and culture negative, and 1 was MTD negative and culture positive, indicating a sensitivity of 97.2% and a specificity of 96.1% for the MTD. After resolution of discrepant results by review of the patients' clinical data, the sensitivity of the MTD was 93.9%, the specificity was 97.6%, the positive predictive value was 80.7%, and the negative predictive value was 99.3% for the NALC series; the corresponding values were 97.4, 96.9, 76.0, and 99.7%, respectively, for the SDS series. In conclusion, the MTD is a highly sensitive and specific technique for detecting M. tuberculosis complex within hours in both smear-positive and smear-negative respiratory specimens.
The Gen-Probe Amplified Mycobacterium tuberculosis Direct Test (MTD) was adapted to be used for cerebrospinal fluid (CSF) and a large variety of other nonrespiratory specimens. Standardized with artificially spiked dilution series of CSF, the modified MTD procedure consists of (i) increasing the amount of sample 10-fold, (ii) pretreating the specimen with a detergent, and (iii) increasing the amplification time from 2 to 3 h. Performance of MTD in a clinical mycobacteriology laboratory was tested over an extended period of time, involving a total of 322 nonrespiratory as well as 1,117 respiratory specimens from 998 patients. Results from MTD were compared with those from microscopy, culture, analysis of tuberculostearic acid by gas-liquid chromatography-mass spectrometry (CSF only), and the final clinical diagnosis. When MTD results were compared with resolved data, the sensitivity, specificity, and positive and negative predictive values for MTD were 93.1, 97.7, 90.0, and 98.5%, respectively, for nonrespiratory specimens and 86.6, 96.4, 76.8, and 98.1%, respectively, for respiratory specimens. Our data demonstrate that (i) MTD is a robust, highly sensitive and specific technique for the rapid detection of M. tuberculosis complex in all types of clinical specimens, (ii) there was no statistically significant difference (P > 0.005) in sensitivity and specificity for nonrespiratory compared with respiratory specimens, and (iii) repeating all MTDs which yield a result between 30,000 and 200,000 relative light units would help prevent a large number of false positives and, thus, enhance test specificity.
Recovery rates of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens were determined by using the fluorescent BACTEC 9000 MB system. Data were compared to those assessed by the radiometric BACTEC 460 system and by cultivation on solid media. A total of 3,095 specimens were processed with N-acetyl-L-cysteine-NaOH by two laboratories. The contamination rates for the BACTEC 9000 MB system were 6.8% (center 1) and 9.8% (center 2). A total of 451 mycobacterial isolates were detected (Mycobacterium tuberculosis complex, n ؍ 296; nontuberculous mycobacteria [NTM], n ؍ 155). These isolates originated from 94 (20.8%) smear-positive and 357 (79.2%) smear-negative specimens. The BACTEC 9000 MB system was significantly better than solid media (P < 0.05) in detecting AFB, but it was less efficient than the radiometric system (P < 0.01). The BACTEC 9000 MB system plus solid media (combination A) recovered 393 (87.1%) of the isolates, while the BACTEC 460 system plus solid media (combination B) detected 430 (95.3%) of all AFB isolates. Between combination A and B there was no statistically significant difference for the detection of isolates from smear-positive specimens (P > 0.05), in contrast to the recovery of AFB from smear-negative specimens for M. tuberculosis complex, P < 0.05; for NTM, P < 0.01). The mean time to detection of M. tuberculosis complex was 12.2 days for smear-positive specimens and 18.1 days for smear-negative specimens with the BACTEC 9000 MB system; 9.3 and 15.6 days, respectively, with the BACTEC 460 system; and 21.2 and 28.4 days, respectively, with solid media. For NTM, the average detection times were 15.1, 17.3, and 31.3 days by the three methods, respectively. In conclusion, the BACTEC 9000 MB system is a rapid, less labor-intensive detection system which allows for higher levels of recovery of AFB than solid media. There is no risk of cross contamination, which is known to be the case for the BACTEC 460 system, and data management is greatly facilitated. As a whole, however, the BACTEC 9000 MB system should only be used in conjunction with solid media.
This paper analyzes the electrochemical and physicochemical properties of activated carbons developed from coffee husk through different activation routes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.