Measurement of particle size and size distribution of complex drug products exhibiting complex rheological behaviors can be challenging as these properties may be beyond the theoretical assumptions of the measurement technique. Herein cyclosporine (CsA) ophthalmic emulsion was selected as a model complex system, and an in-depth assessment of particle size was performed using five fundamentally different particle sizing techniques, including dynamic light scattering (DLS), laser diffraction (LD), nanoparticle tracking analysis (NTA), cryogenic transmission electron microscopy (Cryo-TEM) and 2-dimensional diffusion ordered spectroscopy nuclear magnetic resonance (2D DOSY-NMR). The effect of various viscosity modifying and stabilizing excipients in the emulsions was assessed using four types of CsA formulations, i.e., 1) no viscosity modifying excipients, 2) carbomer copolymer type A (CCA), 3) Carbopol 1342, or 4) hydroxypropyl methyl cellulose (HMPC). In general, the variability of reported particle size increased, and is not as accurate, for emulsions dispersed in a non-Newtonian fluid and at higher emulsion concentrations. This effect was reduced in part by diluting the samples to lower volume fraction and a more Newtonian regime. To address the concern that sample dilution prior to measurement may induce physical instability in the emulsions, NTA was used to monitor average size at dilutions of up to 1:50,000. The size was found to remain constant and independent of the presence or type of stabilizer used. Cryo-TEM further confirmed that dilution did not alter particle size or morphology. Of the five evaluated techniques, Cryo-TEM and 2D DOSY NMR did not require dilution for measurement. The overestimate in DLS size measurements for certain CsA formulations was attributed to complex dispersant rheological behavior, particle-particle interactions, multiple light scattering events, and/or scattering interference from the polymers, which can be overcome by either testing under dilutions or by selecting one of the techniques less impacted by the interference of polymer.
This is a case of a 67-year-old female with a history of Graves’ disease and associated thyroid eye disease who presented to the emergency room after falling and hitting her head. Subsequently, she noted periorbital air on the left side when blowing her nose. A CT scan in the emergency room revealed a left orbital floor fracture and decompression of the left orbit. While nonsurgical orbital decompression in the setting of Graves’ eye disease has been reported in several instances, spontaneous ethmoid bone remodeling or fracture has been the most cited mechanism, with rarer instances of true spontaneous orbital floor fracture. Furthermore, there exist only two known case reports of traumatic orbital floor fractures with subsequent orbital decompression in the setting of thyroid eye disease. In only one of the two known cases, therapeutic effect was established. However, no significant follow-up period was noted. This case represents a rare traumatic orbital floor fracture resulting in orbital decompression with demonstrably improved exophthalmos. It is the first to include definitive follow-up both before and after operative management of the contralateral orbit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.