Bifunctional derivatives of the chelating agents ethylenediaminetetraacetic acid and diethylenetriaminepentaacetic acid, in which a p-isothiocyanatobenzyl moiety is attached at the methylene carbon atom of one carboxymethyl arm, was synthesized by reductive alkylation of the relevant polyamine with (p-nitrophenyl)pyruvic acid followed by carboxymethylation, reduction of the nitro group, and reaction with thiophosgene. The resulting isothiocyanate derivatives reacted with monoclonal antibody B72.3 to give antibody-chelator conjugates containing 3 mol of chelator per mole of immunoglobulin, without significant loss of immunological activity. Such conjugates, labeled with the radioisotopic metal indium-111, selectively bound a human colorectal carcinoma implanted in nude mice when given intravenously. Uptake into normal tissues was comparable to or lower than that reported for analogous conjugates with known bifunctional chelators. It is concluded that substitution with a protein reactive group at this position in polyaminopolycarboxylate chelators does not alter the chelating properties of these molecules to a sufficient extent to adversely affect biodistribution and thus provides a general method for the synthesis of such chelators.
A retrospective clinical study was conducted to compare results obtained by AxSYM® CA 15-3TM, IMx® CA 15-3 and Truquant® BRTM RIA using surplus serum specimens from healthy volunteers and patients with benign and malignant diseases. Linear regression analysis of AxSYM and IMx CA 15-3 versus Truquant BR RIA for specimens with results 0–250 U/ml gave correlation coefficients of 0.888 and 0.910 and slopes of 0.67 and 0.69, respectively. For specimens with results 0–2,000 U/ml, slopes were 0.95 and 0.91, respectively. Receiver operator characteristic analyses, based on results from healthy females plus nonmalignant disease patients versus breast cancer patients, for all three assays gave essentially equivalent areas under the curves. Concordance between AxSYM or IMx CA 15-3 and Truquant BR RIA was greater than 92%. Serial dilution of seven serum specimens yielded linear regression correlation coefficients ranging from 0.997 to 1.000 for AxSYM and IMx CA 15-3, and from 0.962 to 0.998 for Truquant BR RIA. The average percent CVs of the calculated assay values for the 7 specimens were 4.9, 2.7 and 18.1 for AxSYM CA 15-3, IMx CA 15-3 and Truquant BR RIA, respectively. Average percent recoveries ranged from 96.2 to 110.7 for AxSYM and IMx CA 15-3, and 81.8 to 93.3 for Truquant BR RIA. Although assay values differ between the two methodologies, AxSYM CA 15-3, IMx CA 15-3 and Truquant BR RIA showed comparable trending results for the 24 breast cancer patients evaluated for serial monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.