Recordings of aortic root movement represent one of the first accomplishments of ultrasound in medicine and mark the beginning of functional cardiac imaging. However, the underlying mechanism is not completely understood. Since the aortic root is directly connected to the cardiac skeleton we hypothesize, that the amplitude of systolic aortic root motion (SARM) may be mainly caused by displacement of the cardiac base towards the apex and might therefore be used as measure of left ventricular longitudinal function (LV-LF). One hundred and eighty patients with dilated cardiomyopathy and 180 healthy controls were prospectively included into this study. SARM was lower in patients compared to controls (9 ± 3 mm vs. 12 ± 2 mm, p < 0.001) and lowest in patients with cardiovascular events (9 ± 3 mm vs. 7 ± 3 mm, p < 0.001). During a median follow-up time of 38 months, the combined end-point of cardiovascular death or hospitalization for heart failure was reached by 25 patients (13.9%). Reduced SARM had significant prognostic impact on outcome (hazard ratio 0.74, 95% confidence interval 0.63–0.88, p < 0.001) and remained an independent predictor in the multivariate analysis. Compared to parameters with potential influence on its mechanism, SARM correlated best (r = 0.75, p < 0.001) with global longitudinal strain (GLS). SARM may therefore represent an alternative echocardiographic parameter for the assessment of LV-LF, particularly when GLS is not feasible or apical views are not available.
From the point-of-view of economy and safety it is desirable to employ structural configurations with a favorable strength-to-weight ratio and a sufficiently small imperfection-sensitivity. The presentation focuses on two examples falling into this category: The axially compressed cylindrical shell filled with -and/or surrounded by -a compliant core, and auxetic structures. Both exhibit unexpected aspects in their load-carrying behavior and have a significant weightsavings potential.
Background Cardiac autonomic dysfunction after myocardial infarction identifies patients at high risk despite only moderately reduced left ventricular ejection fraction. We aimed to show that telemedical monitoring with implantable cardiac monitors in these patients can improve early detection of subclinical but prognostically relevant arrhythmic events.
MethodsWe did a prospective investigator-initiated, randomised, multicentre, open-label, diagnostic trial at 33 centres in Germany and Austria. Survivors of acute myocardial infarction with left ventricular ejection fraction of 36-50% had biosignal analysis for assessment of cardiac autonomic function. Patients with abnormal periodic repolarisation dynamics (≥5•75 deg²) or abnormal deceleration capacity (≤2•5 ms) were randomly assigned (1:1) to telemedical monitoring with implantable cardiac monitors or conventional follow-up. Primary endpoint was time to detection of serious arrhythmic events defined by atrial fibrillation 6 min or longer, atrioventricular block class IIb or higher and fast non-sustained (>187 beats per min; ≥40 beats) or sustained ventricular tachycardia or fibrillation. This study is registered with ClinicalTrials.gov, NCT02594488.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.