Applying MARS treatments to patients with acute exacerbation of chronic liver disease can detoxify blood, improve cerebral circulation, and reduce brain edema, as reflected by the reduction in intracranial pressure and jugular bulb oxygen saturation values in our patients. A partial reversal of the characteristic hyperdynamic circulation was also achieved. Despite our encouraging results, further testing is needed to determine the reliability of the system.
We examined the kinetics of shedding of the soluble TNF receptors (TNF-Rs) in response to TNF leakage during isolated limb perfusion procedures and correlated them to the resulting hemodynamic effects. Shedding of the TNF-Rs started 7 min after TNF leakage into the systemic circulation. Three waves of shedding were observed peaking at 1, 8-12, and 48-72 h both in vivo and in cell cultures. The soluble receptors prolonged the half-life of TNF in the systemic circulation to 2.5-6 h. Excess shedding of the p75 compared with p55 TNF-Rs was noted during the first wave. The amount and speed of shedding of the p75 TNF-Rs were proportional to the serum TNF levels (P < 0.001). A maximal shedding capacity was attained only during the first wave of shedding, at TNF concentrations of approximately 1.5 ng/ml. Above this level, the linearity between TNF and its soluble receptors was lost. TNF-induced hypotension coincided with the initial imbalance between the concentrations of TNF and its soluble receptors. Despite the spontaneous correction of this imbalance at 8-12 h, the hemodynamic and biochemical alterations persisted and were further aggravated at 18 h, suggesting that other factors induced earlier by TNF are responsible for the perpetuation of the hemodynamic instability. This study may provide the basis for a more physiological therapeutic approach to TNF neutralization in septic shock patients.
Background: We assessed outcome of patients with moderate and severe COVID-19 following treatment with convalescent plasma (CP) and the association with IgG levels in transfused CP. Methods: A prospective cohort study. Primary outcome was improvement at day 14 defined as alive, not on mechanical ventilation, and moderate, mild, or recovered from COVID-19. Antibody levels in CP units were unknown at the time of treatment. IgG against the spike protein S1 was subsequently measured by ELISA. Neutralizing antibodies titers were determined in a subset. Outcome was assessed in relation to the mean antibody level transfused to the patients (4.0 versus >4.0). Findings: Of 49 patients, 11 (22.4%) had moderate, 38 (77.6%) had severe disease, 28 were ventilated. At day 14, 24 (49.0%) patients improved, 9 (18.4%) died, and 13 (26.5%) were ventilated. In 14/98 (14.3%) CP units
Both drugs afforded reliable, safe, and controllable long-term sedation in ICU patients and rapid weaning from mechanical ventilation. Midazolam depressed respiration, allowed better maintenance of sedation, and yielded complete amnesia at a lower cost, while propofol caused more cardiovascular depression during induction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.