Gated detection of the output of a fiber-optic-coupled radiation dosimeter effectively eliminated the direct contribution of Cerenkov radiation to the signal. The radiation source was an external beam radiotherapy machine that provided pulses of 6-MeV x rays. Gated detection was used to discriminate the signal collected during the radiation pulses, including Cerenkov interference, from the signal collected between the radiation pulses due only to phosphorescence from the Cu(1+)-doped glass detector. Gated detection of the long-lived phosphorescence of the Cu(1+)-doped glass provided real-time dose measurements that were linear with the absorbed dose and that were accurate for all field sizes studied.
A novel approach for the fabrication of high-quality preforms for use in the fabrication of photonic crystal fibers is described. The preforms are fabricated in a multistep process that involves stacking a bundle with rods and (or) tubes of two dissimilar glasses, fusing the bundle, and then etching the fused bundle in acid to remove one of the two glasses. The procedure for fabrication of the fused preforms is similar to that used in the fabrication of microchannel plate glass and yields periodically spaced, uniform, round channels that extend through the length of the preform.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.