Colorectal cancers typically metastasize to the lymph nodes, liver or lungs. Metastasis to the heart is rare and although a few cases of cardiac metastases from colon cancer are described in the literature, cases of metastatic rectal cancer to the heart are far fewer. A 69-year-old woman with a history of rectal adenocarcinoma treated with neo-adjuvant chemotherapy and radiation, followed by resection and adjuvant chemotherapy, presented with increasing dyspnea on exertion and lower extremity edema 5 years after oncology follow-up. Echocardiography revealed a mass within the right atrium, which was biopsied and found to be consistent with metastatic rectal adenocarcinoma and a thrombus. The patient was deemed to be a poor surgical candidate given her co-morbidities and overall prognosis. Chemotherapy was offered and refused by the patient. The medical literature has a paucity of similar cases of rectal adenocarcinoma metastasizing to the right atrium. Further studies are needed to help guide standardized treatment options.
Background: Transbronchial forceps biopsy is the widely accepted modality for obtaining tissue specimens for the evaluation of unexplained lung parenchymal abnormalities. However, cryoprobe biopsy provides large specimen sizes and higher yield performance. Utilization of cryoprobe biopsy remains limited by its need to be performed under rigid bronchoscopy and subsequent required operator expertise. We evaluated whether a larger, 2.8 mm forceps could be utilized for parenchymal biopsies. A larger size would surrogate the cryoprobe's large sample size and forceps mechanism to obviate the need for rigid bronchoscopy and its requirement for removing the sample en bloc.Methods: This prospective, randomized controlled, single-blinded porcine study compared a 1.9 mm cryoprobe, a 2.4 mm cryoprobe, and a 2.8 mm forceps. Assessment of histopathologic quality, sample quality and surface area, attempts to retrieve specimen samples, fluoroscopy activation time, overall procedural time, and complications were compared.Results: Although cryoprobe yielded larger specimens, there was no statistical difference amongst all tools with respect to alveolar tissue surface area. There was bleeding on all cryoprobe biopsies. No bleeding was observed with forceps. Out of 32 potential combinations of interventions for bleeding control, 18 (56.3%) were made. There was no significant difference in sample quality between all three modalities. There was one pneumothorax in the forceps arm.Conclusions: Large forceps (LF) biopsy is a feasible technique while providing high diagnostic yield without the need for advanced therapeutic tools. Human studies are needed to further corroborate this technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.