Background The aim of the study was to investigate the issue of medial midvastus (MMV) vs. medial parapatellar (MPP) approaches in total knee arthroplasty (TKA). It was hypothesized that the two surgical approaches would produce significantly different results with respect to patient-reported knee score outcome (hypothesis 1), short-term postoperative range of motion (ROM) (hypothesis 2), long-term postoperative ROM (hypothesis 3) and prosthesis survival (hypothesis 4). Methods A retrospective comparative study design was applied. Data sets were obtained from the state arthroplasty registry. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC) data were analyzed from preoperative and 1 year postoperatively. The ROM data were analyzed for the time points preoperative, postoperative days 4 and 10 and 1 year. Results Available were 627 cases (407 MMV vs. 220 MPP) and 1 year postoperatively there were no significant differences between groups regarding the WOMAC scores (hypothesis 1). Early postoperatively on days 4 and 10 after TKA there were no differences between groups (p = 0.305 and p = 0.383, respectively, hypothesis 2). Likewise, ROM did not significantly differ between the groups 1 year after TKA (p = 0.338, hypothesis 3). The 5‑year prosthesis survival did not differ between the groups and showed 94.46% (95% confidence interval, CI 90.69–96.73%) in the MMV group and 94.33% (95% CI 89.96–96.83%) in the MPP group (p = 0.664, hypothesis 4). Conclusion Both surgical approaches produce equivalent clinical results in terms of early postoperative ROM, late postoperative ROM and 1‑year WOMAC. The same prosthesis survival rates can be expected.
Background: Intraosseous access is a recommended alternative to venous access in emergencies. For its application, knowledge of the correct insertion depth is indispensable. We aimed to determine sex-specific differences on the appropriate insertion depth for intraosseous access in adults at the insertion sites most frequently used, namely the proximal and distal tibia and the proximal humerus. Methods: In this exploratory retrospective study, we measured thickness of soft tissue cover, cortex and cancellous bone along the puncture line on magnetic resonance images or computed tomography scans. Inclusion criteria were both sexes, 18–90 years of age and appropriate image quality. Primary outcome was the appropriate insertion depth to reach the cancellous bone for each sex. This was defined as the corridor between (i) the sum of the soft tissue cover and the cortex and (ii) the sum of (i) plus the diameter of the cancellous bone. Secondary outcomes were the differences in thickness of each layer between sexes. Results: In 179 females and males, the appropriate insertion depth was 32.5–45.5 mm and 20.5–42.0 mm in the proximal tibia, 14.5–30.5 mm and 16.5–34.5 mm in the distal tibia, and 27.5–52.5 mm and 26.0–56.5 mm in the proximal humerus. Although females had a thicker soft tissue cover (+6.8 mm [95% CI 3.7–10.1], p < 0.01) in the proximal tibia, extrapolation by correlation analysis showed no clinically relevant difference between the sexes. Conclusion: In adults, there are no sex-specific differences in the appropriate insertion depth for intraosseous access in the proximal or distal tibia or in the proximal humerus.
Purpose Arthroplasty registries gained increasing importance to the re-certification of orthopaedic implants according to the European Union (EU) Medical Device Regulation (MDR) adopted in 2017. Until recently, several European countries only had regional arthroplasty registries. Whether regional registries deliver data quality comparable with national registries remained unclear. Therefore, the purpose of this study was to validate the Austrian Tyrolean Hip Arthroplasty Registry (THAR) and to evaluate if this regional registry showed adequate adherence, completeness and correctness when compared with well-established national registries. Methods A consecutive series of 1100 primary total hip arthroplasties were identified from our institution’s medical database. Patients were interviewed by phone and completed questionnaires after a mean follow-up period of 8.05 years and were asked if they had had revision surgeries. The data were compared to the corresponding dataset from the THAR. Results Adherence was 97.91% for primary total hip arthroplasty. Clinical follow-up identified 10 missing cases, resulting in adherence of 81.48% for revisions. Completeness of patient-reported outcome measurements was 78.55% before surgery and 84.45% 1 year after surgery. Correctness was 99.7% for demographic data, 99.54% for implant specifications, and 99.35% for mode of fixation. Conclusion The data of this study showed that regional arthroplasty registries can deliver data quality comparable with well-established national registries. The main reason for unrecorded revision cases and wrongly recoded implants was human error. Further digitalization with more automatic data submission may have the potential to reduce these failure rates in the future. Overall, the THAR represents a valid data source for re-certification of medical implants according to the EU’s MDR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.