Self expanding Transcatheter Aortic Valve Replacements (TAVR) can conform to the geometry of the aortic annulus and the calcified leaflet complex, which may result in leaflet distortion and altered leaflet kinematics, but such changes have not yet been characterized. In this study we developed a computational model to investigate the deployment of a self expanding TAVR in a realistic aortic root model derived from multi-slice computed tomography (MSCT) images. We simulated TAVR crimping/deployment in realistic and idealized aortic root models, followed by diastolic loading of the TAVR leaflets in its final deployed configuration. The TAVR deployed in a realistic aortic root had increased peak loading in the commissural region of the leaflets compared to TAVRs under idealized circular deployment conditions (2.97 vs. 1.52 MPa). Furthermore, orientation of the TAVR in the asymmetric aortic annulus such that the commissures of the TAVR are aligned with the native valve commissures minimized the effect of TAVR stent distortion on peak stresses in the TAVR leaflets (2.97 vs. 2.35 MPa). We propose that preoperative planning of the orientation of the TAVR in the aortic root annulus might minimize the impact of potential stent distortion on leaflet function and may in turn increase long term leaflet durability.
Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell damage. Particle Image Velocimetry was used to quantitatively characterize fluid velocity fields, shear stress and turbulent kinetic energy downstream of TAVRs deployed in circular and eccentric orifices representative of deployed TAVRs in vivo. Effective orifice area (EOA) and mean transvalvular pressure gradient (TVG) values did not differ substantially in circular and eccentric deployed valves, with only a minor decrease in EOA observed in the eccentric valve (2.0 cm(2) for circular, 1.9 cm(2) for eccentric). Eccentric deployed TAVR lead to asymmetric systolic jet formation, with increased shear stresses (circular = 97 N/m(2) vs. eccentric = 119 N/m(2)) and regions of turbulence intensity (circular = 180 N/m(2) vs. eccentric = 230 N/m(2)) downstream that was not present in the circular deployed TAVR. The results of this study indicate that eccentric deployment of TAVRs can lead to altered flow characteristics and may potentially increase the hemolytic potential of the valve, which were not captured through hemodynamic evaluation alone.
A simple, low-cost, web-delivered sleep intervention is feasible and significantly improves sleep quality and measures of psychosocial health in individuals with mild sleep impairment but does not result in short-term improvements in blood pressure.
The durability of bovine pericardium leaflets employed in bioprosthetic heart valves (BHVs) can significantly limit the longevity of heart valve prostheses. Collagen fibres are the dominant load bearing component of bovine pericardium, however fibre architecture within leaflet geometries is not explicitly controlled in the manufacture of commercial devices. Thus, the purpose of this study was to ascertain the influence of pre-determined collagen fibre orientation and dispersion on the mechanical performance of bovine pericardium. Three tissue groups were tested in uniaxial tension: cross-fibre tissue (XD); highly dispersed fibre-orientations (HD); or preferred-fibre tissue (PD). Both the XD and PD tissue were tested under cyclic loading at 1.5 Hz and a stress range of 2.7 MPa. The results of the static tensile experiments illustrated that collagen fibre orientation and degree of alignment significantly influenced the material's response. Whereby, there was a statistically significant decrease in material properties between the XD groups and both the PD and HD groups for ultimate tensile strength and stiffness (p<0.01). Furthermore, HD tissue had a stiffness of approximately 58% of the PD group, and XD tissue had a stiffness of approximately 18% of the PD group. The dynamic behaviour of the XD and PD groups was extremely distinct; for example a Weibull analysis indicated that the 50% probability of failure in specimens with fibres orientated perpendicular (XD) to the loading direction occurred at 375 cycles. Due to this failure, XD specimens survived less than 20% of the cycles completed by those in which fibres were aligned along the loading direction (PD). The results from this study indicate that fibre architecture is a significant factor in determining static strength and fatigue life in bovine pericardium, and thus must be incorporated in the design process to improve future device durability.
Medical nutritional therapy and exercise for women with GDM may be successful in lowering rates of large for gestational age and macrosomia without increasing small-for-gestational-age rates. Women with GDM and a BMI less than 25 kg/m(2) had outcomes similar to those with NGT suggesting that these women could potentially be treated in a less resource intensive setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.