In pandemics, centralized healthcare leadership is a critical requirement. The objective of this study was to analyze the early development, operation, and effectiveness of a COVID-19 organizational leadership team and transformation of healthcare services at West Virginia University Hospitals and Health System (WVUHS). The analysis focused on how Kotter's Leading Change eight-stage paradigm could contribute to an understanding of the determinants of successful organizational change in response to the COVID-19 pandemic. Methods: The fifteen core leaders of WVUHS COVID-19 strategic system were interviewed. A qualitative thematic analysis of the interviews was used to evaluate key aspects of leadership dynamics and system-wide changes in healthcare policies and protocols to contain the pandemic. Outcome measures included the degree to which WVUHS could handle and contain COVID-19 cases as well as COVID-19 death and vaccination rates in West Virginia compared with other states. Results: The leadership team radically and rapidly revamped nearly all healthcare policies, procedures, and protocols for WVUHS hospitals and clinics, and launched a Hospital Incident Command System. As a result of this effective leadership team and strategic plan, WVUHS surge capacity was adequate for COVID-19 cases. In addition, West Virginia was an early frontrunner in COVID-19 vaccination rates as well as lower death rates. Conclusion: WVUHS's leadership response to the COVID-19 pandemic followed Kotter's eight-stage paradigm for Leading Change in organizations, including the establishment of a sense of urgency, formation of a powerful guiding coalition, creation of a vision, communication of the vision, empowerment of others to act on the vision, plan for and creation of short-term wins, consolidation of improvements and production of more changes, and institutionalization of new approaches. This approach was effective in limiting the spread and impact of COVID-19 within the hospital network and across the state, with many lessons learned along the way.
Background: Antifibrinolytics such as tranexamic acid and epsilon-aminocaproic acid are effective at reducing blood loss and transfusion in pediatric patients having craniofacial surgery. The Pediatric Craniofacial Collaborative Group has previously reported low rates of seizures and thromboembolic events (equal to no antifibrinolytic given) in open craniofacial surgery. Aims: To query the Pediatric Craniofacial Collaborative Group database to provide an updated antifibrinolytic safety profile in children given that antifibrinolytics have become recommended standard of care in this surgical population. Additionally, we include the population of younger infants having minimally invasive procedures. Methods: Patients in the Pediatric Craniofacial Collaborative Group registry between June 2012 and March 2021 having open craniofacial surgery (fronto-orbital advancement, mid and posterior vault, total cranial vault remodeling, intracranial LeFort III monobloc), endoscopic cranial suture release, and spring mediated cranioplasty were included. The primary outcome is the rate of postoperative complications possibly attributable to antifibrinolytic use (seizures, seizure-like activity, and thromboembolic events) in infants and children undergoing craniosynostosis surgery who did or did not receive antifibrinolytics.Results: Forty-five institutions reporting 6583 patients were included. The overall seizure rate was 0.24% (95% CI: 0.14, 0.39%), with 0.20% in the no Antifibrinolytic group and 0.26% in the combined Antifibrinolytic group, with no statistically reported difference. Comparing seizure rates between tranexamic acid (0.22%) and epsilon-aminocaproic acid (0.44%), there was no statistically significant difference (odds ratio = 2.0; 95% CI: 0.6, 6.7; p = .257). Seizure rate was higher in patients greater than 6 months (0.30% vs. 0.18%; p = .327), patients undergoing open procedures (0.30% vs. 0.06%; p = .141), and syndromic patients (0.70% vs. 0.19%; p = .009).
Background Tracheal intubation carries an elevated risk of exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) due to the generation of aerosols containing high concentrations of the virus. An airway box was designed to mitigate the exposure of healthcare professionals performing intubations. Aim We evaluated usability and sustainability in the routine practice of the "airway box" as a protective device during high-risk airway procedures. Materials and methods After institutional review board approval, clinicians were educated on using the device through simulation, intranet learning modules, and emailed resources. The airway box was made available in the emergency department, critical care units, perioperative area, and operating rooms. QR codes affixed to the box, emailed, and displayed in common areas provided easy access to complete a REDcap survey (Vanderbilt University Nashville, USA) eliciting providers' experience. Data was collected and analyzed between April 1 and July 31, 2020, on REDcap, and the results were analyzed. Results 687 emergent intubations took place. 232 were performed by anesthesiologists, 315 by emergency department providers, and 140 by critical care specialists. 39 surveys were completed, 29 from intubations in the operating room, three from the critical care units, five from interventional radiology suites, and two perioperatively. Providers found the device to be readily available, with a score of 4.51/5, and the majority of providers, 60%, found the device easy to use, rating it either a 4 or 5 out of 5. Providers acquired a mean Mallampati score of 1.75 and 1.40 mean laryngoscopic grade view. Conclusion Intubation boxes may effectively mitigate high-risk viral exposure during airway procedures. Survey responses show that devices were easy to use and did not significantly affect visualization of the airway. Similar to mask use, enclosure devices in clinical practice could become a vital part of medical protective equipment even after the SARS-CoV-2 pandemic if they are effectively implemented.
A 73-year-old female patient presented for mitral valve replacement and coronary artery bypass grafting secondary to multivessel coronary disease and severe mitral valve regurgitation with moderate stenosis. After bypass, the patient developed refractory hypotension with decreased biventricular volume and elevated central venous pressure (CVP). Transesophageal echocardiography (TEE) was utilized to make the diagnosis of acute intraoperative superior vena cava (SVC) syndrome. The SVC cannulation site was revised, resulting in resolution of the hypotension and a decrease in the CVP. Intraoperative TEE was vital in recognizing, managing, and ultimately repairing the acute intraoperative SVC stenosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.