Aims Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. Methods In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component. Results Mean polyethylene wear in the proximal direction was 0.17 mm (SD 0.15) for the VEPE group and 0.20 mm (SD 0.09) for the ModXLPE group (p = 0.005) at five years. Annual proximal wear rates were 0.03 mm/year (VEPE) and 0.04 mm/year (ModXLPE). Total 3D wear was 0.21 mm (SD 0.26) and 0.23 mm (SD 0.10) for the VEPE and ModXLPE groups, respectively (p = 0.009). Total 3D cup translation was 0.72 mm (SD 0.70) (VEPE) and 0.50 mm (SD 0.44) (ModXLPE) (p = 0.409). Conclusion At five years, there was less polyethylene wear in the VEPE group than in the ModXLPE group. Both VEPE and ModXLPE cemented components showed low annual wear rates. Component stability was similar in the two groups and remained constant up to five years. Whether these results will equate to a lower long-term revision rate is still unknown. Cite this article: Bone Joint J 2020;102-B(12):1646–1653.
Wear of this vitamin E-infused highly cross-linked polyethylene is still low at 6-year follow-up, with no significant difference in wear from 3 months to 6 years between 32- and 36-mm heads.
Background and purpose: Dislocation of a hip prosthesis is the 3rd most frequent cause (after loosening and infection) for hip revision in Norway. Recently there has been a shift in surgical practice including preferred head size, surgical approach, articulation, and fixation. We explored factors associated with the risk of revision due to dislocation within 1 year and analyzed the impact of changes in surgical practice.Patients and methods: 111,711 cases of primary total hip arthroplasty (THA) from the Norwegian Arthroplasty Register were included (2005–2019) after primary THA with either 28 mm, 32 mm, or 36 mm femoral heads, or dualmobility articulations. A flexible parametric survival model was used to calculate hazard ratios for risk factors. Kaplan–Meier survival rates were calculated.Results: There was an increased risk of revision due to dislocation with 28 mm femoral heads (HR 2.6, 95% CI 2.0–3.3) compared with 32 mm heads. Furthermore, there was a reduced risk of cemented fixation (HR 0.6, CI 0.5–0.8) and reverse hybrid (HR 0.6, CI 0.5–0.8) compared with uncemented. Also, both anterolateral (HR 0.5, CI 0.4–0.7) and lateral (HR 0.6, CI 0.5–0.7) approaches were associated with a reduced risk compared with the posterior approach. The time-period 2010–2014 had the lowest risk of revision due to dislocation. The trend during the study period was towards using larger head sizes, a posterior approach, and uncemented fixation for primary THA.Interpretation: Patients with 28 mm head size, a posterior approach, or uncemented fixation had an increased risk of revision due to dislocation within 1 year after primary THA. The shift from lateral to posterior approach and more uncemented fixation was a plausible explanation for the increased risk of revision due to dislocation observed in the most recent time-period. The increased risk of revision due to dislocation was not fully compensated for by increasing femoral head size from 28 to 32 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.