Introduction
Mandibular Advancement Devices (MAD) have been reported to be an alternative treatment to CPAP in moderate to severe obstructive sleep apnea (OSA) cases. The design of MAD has a major influence on its success rate on the patient, and design features that have an influence on efficacy, tolerance, and compliance. The aim of this study was to determine the range of mandibular protrusion at different vertical points; 2, 5, 8 and 11 mm in a young adult population.
Methods
Fifty two students aged 19 to 23 years (mean 21.3 ± 1.7; 29 females and 23 males), with full permanent dentition participated in the study. The absolute range of maximal mandibular protrusion and retrusion was measured (mm) with the use of the George Gauge. Descriptive statistics, ANOVA and paired t-test using SPSS were used.
Results
Range of mandibular advancement was possible to be determined for the 4 levels of vertical opening with the gauges: 2 mm fork mean mandibular advance 13,10 mm ± 0.604; 5 mm mean 11.98 mm ± 1.075; 8 mm mean 11.20 mm ± 1.369; 11 mm mean 9.87 mm ± 1.886. No significant differences were found between class I, II, and III.
Conclusions
There is an impact of increased inter-incisal distance of effective mandibular protrusion when constructing a MAD. As vertical dimension increases the mandible rotates posteriorly and places itself in a more retrusive location, and the range of mandibular advancement reduces (0.3 mm for every 1 mm of vertical increase).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.