Background:
Mechanical injury in the conduction system requiring permanent pacemaker (PPM) associated with transcatheter aortic valve replacement (TAVR) procedure is a common complication. The objective of this study was to use ambulatory monitor BodyGuardian to assess late occurrence of atrioventricular block (AVB) after TAVR.
Methods:
This prospective study evaluated 365 patients who underwent TAVR at Mayo Clinic, Rochester, Minnesota between June 2016 and August 2017. Patients who received PPM for bradycardia after TAVR before discharge were considered as the PPM group. Those not requiring PPM received a BodyGuardian system (BodyGuardian group) for 30 days of continuous monitoring. Primary end point was Mobitz II or third-degree atrioventricular block (II/III AVB) at 30-day follow-up.
Results:
Of 365 patients, 74 who had a PPM or an implantable cardioverter-defibrillator before TAVR and 94 who were enrolled in other studies were excluded. Of 197 patients enrolled in the study, 70 (35.5%) received PPM and 127 had BodyGuardian before the hospital dismissal. Eleven of 127 (8.6%) BodyGuardian group required PPM within 30 days after TAVR for late occurrence of symptomatic bradycardia. In total, 33 of 197 (16.7%) patients developed II/III AVB (24 before and 9 after discharge). Thirty-four patients had preexisting right bundle branch block. Of them, 16 (47%) developed II/III AVB. Of 53 patients who developed new left bundle branch block after TAVR, 14% progressed to II/III AVB within 30 days.
Conclusions:
In patients without a standard post-TAVR pacing indication, yet a potential risk to develop AVB, a strategy of 30-day monitoring identifies additional patients who require permanent pacing.
Cardioneuroablation (CNA) is proposed as a promising therapy for patients with sinoatrial node dysfunction (SND) that is mediated by excessive vagal tone. However, a series of urgent questions about CNA remain unanswered. From December 2020 to March 2022, six patients with symptomatic SND who underwent CNA were summarized in this report. Sequential CNA targeting Ao-SVC GP, PMLGP, RAGP, and LSGP was performed in patients, guided by fractionated intracardiac electrograms and dynamically evaluated by extracardiac vagal stimulation (ECVS). The results showed that Ao-SVC GP ablation led to a significant increase in heart rate (HR) and the elimination of sinus arrest evoked by ECVS, while the vagal responses of atrial ventricular block were eliminated by the ablation of PMLGP and LSGP. Post-procedure HR increased up to 64–86% of the maximum HR of an atropine test at baseline. The median HR from Holter monitoring increased from 52.8 ± 2.1 bpm at baseline to 73.0 ± 10.4 bpm after the procedure (p = 0.012) and to 71.3 ± 10.1 bpm at the six-month follow-up (p = 0.011). Bradycardia-related symptoms disappeared in all patients at the six-month follow-up. This case series reveals the feasibility of using the ECVS-assisted sequential CNA technique and indicates the critical role of ECVS in dynamically evaluating the impact of sequential CNA on the vagal control of SAN and AVN.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.