On the basis of our biomechanical analysis, the optimal thickness of a cartilage graft for myringoplasty appears to be 0.1 to 0.2 mm for medium and large TM perforations. For small perforations, a cartilage of less than 1.0 mm is a good compromise between mechanical stability and low acoustic transfer loss.
The purpose of this study was to determine the acoustic transfer characteristics of cartilage for optimal cartilage myringoplasty. In order to do so, we developed a cartilage plate/tympanic membrane-coupled model using finite element analysis. Cartilage specimens of the tragus were obtained from fresh human cadavers, and the parameters of the tragus were determined by curve fitting and cross-calibration. A cartilage plate was used to repair an eardrum perforation, and the new coupled tympanic membrane-cartilage complex was loaded into our 3-dimensional biomechanical model of the middle ear for analysis. Our results show that first the β-damping value of the cartilage plate depends on frequency. The value of β damping was close to 3 × 10–4 s at lower frequencies and 5 × 10–6 s at higher frequencies. Secondly, reducing cartilage thickness leads to an improvement of its acoustic transfer qualities. From an acoustics point of view, the 0.1- to 0.2-mm cartilage plate seems to be most preferable with regard to tympanic membrane vibration. Furthermore, thicknesses of 0.2 mm at lower frequencies and 0.1 mm at higher frequencies were regarded as good compromises between sufficient mechanical stability and low acoustic transfer loss.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.