AimsInfection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population.Methods and resultsSince 1982, all PM implantation and removal procedures performed in Denmark have been prospectively recorded in the Danish Pacemaker Register. All patients (n = 46299) who underwent implantation between 1982 and 2007 were included. The total length of surveillance was 236 888 PM-years. The incidence of infection was calculated according to the total number of PM-years. The incidence of surgical site infection (≤365 days after PM implantation) was compared with later infection in first implant and replacement procedures. Multiple-record and multiple-event-per-subject proportional hazards analyses were used to identify the independent risk factors of PM infection. Surgical site infection occurred in 192 cases after first implantation (incidence rate 4.82/1000 PM-years), and in 133 cases after replacement (12.12/1000 PM-years). Infections occurring more than 365 days after the first implantation occurred in 153 cases (1.02/1000 PM-years), and in 118 cases after replacement (3.26/1000 PM-years). Independent factors associated with an increased risk of PM infection were a greater number of PM operations (including replacements), male sex, younger age, implantation during the earliest part of the study period, and absence of antibiotics (P< 0.001).ConclusionThe overall risk of infection after PM implantation was low. A greater number of operations augmented the risk of infection. This should be taken into account when considering revisions of PM systems.
Pneumothorax treated with a chest tube remains a clinically important problem in device therapy. The cephalic vein cut-down technique should be applied whenever possible to avoid this complication.
A total of 220 simultaneous pairs of measurements of cardiac stroke volume were made in twelve women before and during Caesarean section in order to compare impedance cardiography with the thermodilution method. A significantly higher coefficient of correlation was found before (r = 0.77) than during anaesthesia (r = 0.55). Further, there was a significant difference in the slope of the regression lines: before anaesthesia the slope was 1.07 and during anaesthesia with thiopentone, nitrous oxide, oxygen and suxamethonium it was 0.45. Significant changes in the intercept on the Y-axis were found before (-13.9 ml) and during anaesthesia (33.4 ml). When the uterus was displaced upwards and to the left from the 15 degrees tilt position the stroke volume and the cardiac output were increased when measured by both methods to nearly the same values as in the left lateral position. It is concluded that the impedance method is reliable for measuring cardiac stroke volume in late pregnancy under physiological conditions in the conscious patient, but that it cannot replace the thermodilution method in pharmacological studies.
Our results demonstrate that sensitive data such as complications related to pacemaker implantations can be collected on a national basis. We suggest that a reoperation rate higher than 3% for atrial as well as ventricular pacing electrodes in the individual implanting centre should cause the centre to evaluate carefully the procedure as well as the performance of the individual implanter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.