Background: Many skin and mucosal inflammatory disorders, such as atopic dermatitis, have been associated with an impaired epithelial barrier function, which allows allergens, pollutants, or microbes to enter the tissue and activate the immune response. The aim of this study was to establish a method to directly assess in vivo the epidermal barrier function by electrical impedance (EI) spectroscopy.Methods: Mice epidermal barrier was damaged by epicutaneous application of proteases and cholera toxin and by tape stripping. EI and transepidermal water loss (TEWL) were measured before and after the application. Additionally, histological analysis, immunofluorescence staining, and RT-PCR were performed on skin biopsies to evaluate the epithelial barrier.Results: A few hours after papain application, a dose-dependent reduction of EI was detected, reflecting the decreased barrier function. At the same time, an increase of TEWL was observed, with a significant negative correlation with EI, demonstrating that EI changes were directly linked to barrier defects. Twenty-four and 48 hours after the treatment, EI starts to increase to background levels, indicating tissue healing and restoration of skin barrier. Barrier disruption was confirmed by histological analysis showing an impaired stratum corneum and higher cellular infiltration after papain application. In addition, immunofluorescence staining and RT-PCR showed downregulation of molecules involved in the barrier function, such as filaggrin, occludin, and claudin-1, and mRNA levels of filaggrin, loricrin, and involucrin. Comparable results were observed after tape stripping and cholera toxin treatment. Conclusion:Electrical impedance spectroscopy is a rapid and reliable diagnostic tool to detect skin barrier defects. K E Y W O R D S atopic dermatitis, electrical impedance, epithelial barrier, papain, skin inflammation | 1935 RINALDI et AL.
Background: Allergic disorders such as atopic dermatitis (AD) are strongly associated with an impairment of the epithelial barrier, in which tight junctions and/or filaggrin expression can be defective. Skin barrier assessment shows potential to be clinically useful for prediction of disease development, improved and earlier diagnosis, lesion follow-up, and therapy evaluation. This study aimed to establish a method to directly assess the in vivo status of epithelial barrier using electrical impedance spectroscopy (EIS).Methods: Thirty-six patients with AD were followed during their 3-week hospitalization and compared with 28 controls. EIS and transepidermal water loss (TEWL) were measured in lesional and non-lesional skin. Targeted proteomics by proximity extension assay in serum and whole-genome sequence were performed.Results: Electrical impedance spectroscopy was able to assess epithelial barrier integrity, differentiate between patients and controls without AD, and characterize lesional and non-lesional skin of patients. It showed a significant negative correlation with TEWL, but a higher sensitivity to discriminate non-lesional atopic skin from controls.During hospitalization, lesions reported a significant increase in EIS that correlated with healing, decreased SCORAD and itch scores. Additionally, EIS showed a significant inverse correlation with serum biomarkers associated with inflammatory pathways that may affect the epithelial barrier, particularly chemokines such as CCL13, CCL3, CCL7, and CXCL8 and other cytokines, such as IRAK1, IRAK4, and FG2, which were significantly high at admission. Furthermore, filaggrin copy numbers significantly correlated with EIS on non-lesional skin of patients. | 3067 RINALDI et AL.
Skin is easily accessible for transdermal drug delivery and also attractive for biomarker sampling. These applications are strongly influenced by hydration where elevated hydration generally leads to increased skin permeability. Thus, favorable transdermal delivery and extraction conditions can be easily obtained by exploiting elevated skin hydration. Here, we provide a detailed in vivo and in vitro investigation of the skin hydration dynamics using three techniques based on electrical impedance spectroscopy. Good correlation between in vivo and in vitro results is demonstrated, which implies that simple but realistic in vitro models can be used for further studies related to skin hydration (e.g., cosmetic testing). Importantly, the results show that hydration proceeds in two stages. Firstly, hydration between 5 and 10 min results in a drastic skin impedance change, which is interpreted as filling of superficial voids in skin with conducting electrolyte solution. Secondly, a subtle impedance change is observed over time, which is interpreted as leveling of the water gradient across skin leading to structural relaxation/changes of the macromolecular skin barrier components. With respect to transdermal drug delivery and extraction of biomarkers; 1 h of hydration is suggested to result in beneficial and stable conditions in terms of high skin permeability and extraction efficiency.
Medical device (MD) is a broad term that encompasses products ranging from, for example, examination gloves to digital dermoscopy systems; all of which are regulated by a new regulatory framework in the EU from May 2021. The new Medical Device Regulation (MDR) (Regulation EU 2017/745) will have a significant effect on suppliers of MD and will have subsequent effects also for dermatologists and other clinicians. Medical device software and apps are reclassified leading to more stringent requirements on documentation within, e.g. clinical evidence, as well as regulatory authority control. The changes will likely have positive effects on quality, to the benefit of patients. There will, however, be implications affecting the availability and support of existing devices and the introduction of new devices, as well as a likely price increase due to the higher costs for suppliers. Dermatologists, other clinicians and administrators need to be aware of the effects of MDR to ensure that existing devices and new purchases can be used as planned. Specifically, clinicians need to be aware of the following: (i) improved quality of MD and follow-up of incidents can be expected. (ii) Only 'nonsignificant' updates will be permitted after May 2021 to many existing systems and devices unless approved under the new MDR. (iii) Existing devices that do not achieve approval under the new regulation will no longer be manufactured after May 2024. (iv) New products and methods will take longer time to be approved and available. (v) Prices will likely increase. (vi) Suppliers of products that do not fulfil the new regulation will disappear, and the availability of consumables, spare parts or upgrades might be discontinued. (vii) A trend to oligopoly may appear in the market. It is therefore important to check with your suppliers as to how and when they will adhere to the new MDR regulation.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.