Interleukin-10 is a versatile adjuvant candidate to control the post-injurious environment in cartilage defects and promote chondrogenesis in ACI grafts.
Joint injury is a complex process involving specific mechanical effects on cartilage as well as induction of an inflammatory environment. IL-10 prevented crucial mechanisms of chondrodegeneration induced by an injurious single compression. IL-10 might be a multipurpose drug candidate for the treatment of cartilage-related sports injuries or osteoarthritis (OA).
Background: The treatment of osteochondral defects (OCDs) constitutes a major problem for orthopaedic surgeons. The altered mechanics and the cell types, with associated soluble factors derived from the exposed subchondral bone, are likely responsible for the mechanically and structurally inferior articular cartilage subsequently obtained as a repair tissue. There is therefore an unmet clinical need for bioresponsive biomaterials that allow cell delivery, reduce cell infiltration from the bone marrow, and support chondrogenesis in the presence of joint mechanical loading. Purpose: To develop a cell-laden injectable biomaterial, with bioadhesive properties, low cell invasion, and good mechanoresilience, in which simulated joint loading could induce tissue maturation through the production and activation of transforming growth factor beta 1 (TGF-β1). Study Design: Controlled laboratory study. Methods: Human bone marrow–derived mesenchymal stromal/stem cells were encapsulated in tyramine-modified hyaluronic acid (HA-Tyr) hydrogels, with crosslinking initiated by the addition of horseradish peroxidase (HRP) and various concentrations of hydrogen peroxide (H2O2; 0.3-2 mM). Cytocompatibility and biomechanical and adhesive properties were analyzed by live/dead staining, rheology, and push-out test, respectively. For multiaxial loading, cell-laden hydrogels were subjected to 10% compression superimposed onto a 0.5-N preload and shear loading (±25°) at 1 Hz for 1 hour per day and 5 times a week for 4 weeks. TGF-β1 production and activation were measured by enzyme-linked immunosorbent assay (ELISA). Results: The viscoelastic properties of the cell-laden HA-Tyr hydrogels, as crosslinked with different ratios of HRP and H2O2, were demonstrated for a range of cell densities and HRP/H2O2 concentrations. In the absence of serum supplementation, cell invasion into HA-Tyr hydrogels was minimal to absent. The bonding strength of HA-Tyr to articular cartilage compared favorably with clinically used fibrin gel. Conclusion: HA-Tyr hydrogels can be mechanically conditioned to induce activation of endogenous TGF-b1 produced by the embedded cells. HA-Tyr hydrogels function as cell carriers supporting biomechanically induced production and activation of TGF-β1 and as bioadhesive materials with low cell invasion, suggesting that they hold promise as a novel biomaterial for OCD repair strategies. Clinical Relevance: Leveraging physiological joint mechanics to support chondrogenic graft maturation in an optimized mechanosensitive hydrogel in the absence of exogenous growth factors is of highest interest for OCD repair.
Background: Both the superficial medial collateral ligament (sMCL) and the deep MCL (dMCL) contribute to the restraint of anteromedial (AM) rotatory instability (AMRI). Previous studies have not investigated how MCL reconstructions control AMRI. Purpose/Hypothesis: The purpose was to establish the optimal medial reconstruction for restoring normal knee kinematics in an sMCL- and dMCL-deficient knee. It was hypothesized that AMRI would be better controlled with the addition of an anatomically shaped (flat) sMCL reconstruction and with the addition of an AM reconstruction replicating the function of the dMCL. Study Design: Controlled laboratory study. Methods: A 6 degrees of freedom robotic system equipped with a force-torque sensor was used to test 8 unpaired knees in the intact, sMCL/dMCL sectioned, and reconstructed states. Four different reconstructions were assessed. The sMCL was reconstructed with either a single-bundle (SB) or a flattened hamstring graft aimed at better replicating the appearance of the native ligament. These reconstructions were tested with and without an additional AM reconstruction. Simulated laxity tests were performed at 0°, 30°, 60°, and 90° of flexion: 10 N·m valgus rotation, 5 N·m internal and external rotation (ER), and an AM drawer test (combined 134-N anterior tibial drawer in 5 N·m ER). The primary outcome measures of this force-controlled setup were anterior tibial translation (ATT; in mm) and axial tibial rotation (in degrees). Results: Sectioning the sMCL/dMCL increased valgus rotation, ER, and ATT with the simulated AM draw test at all flexion angles. SB sMCL reconstruction was unable to restore ATT, valgus rotation, and ER at 30°, 60°, and 90° of flexion to the intact state ( P < .05). Flat MCL reconstruction restored valgus rotation at all flexion angles to the intact state ( P > .05). ER was restored at all angles except at 90°, but ATT laxity in response to the AM drawer persisted. Addition of an AM reconstruction improved control of ATT relative to the intact state at all flexion angles ( P > .05). Combined flat MCL and AM reconstruction restored knee kinematics closest to the intact state. Conclusion: In a cadaveric model, AMRI resulting from an injured sMCL and dMCL complex could not be restored by an isolated SB sMCL reconstruction. A flat MCL reconstruction or an additional AM procedure, however, better restored medial knee stability. Clinical Relevance: In patients evaluated with a combined valgus and AM rotatory instability, a flat sMCL and an additional AM reconstruction may be superior to an isolated SB sMCL reconstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.