SummaryCutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. Although they are uncommon, they do exist, and require appropriate and complete evaluation. This review summarizes the evidence regarding evaluation tools, especially patch and lymphocyte transformation tests, for hypersensitivity reactions to implanted metal devices. Patch test evaluation is the gold standard for metal hypersensitivity, although the results may be subjective. Regarding pre-implant testing, those patients with a reported history of metal dermatitis should be evaluated by patch testing. Those without a history of dermatitis should not be tested unless considerable concern exists. Regarding post-implant testing, a subset of patients with metal hypersensitivity may develop cutaneous or systemic reactions to implanted metals following implant. For symptomatic patients, a diagnostic algorithm to guide the selection of screening allergen series for patch testing is provided. At a minimum, an extended baseline screening series and metal screening is necessary. Static and dynamic orthopaedic implants, intravascular stent devices, implanted defibrillators and dental and gynaecological devices are considered. Basic management suggestions are provided. Our goal is to provide a comprehensive reference for use by those evaluating suspected cutaneous and systemic metal hypersensitivity reactions.Key words: allergic contact dermatitis; implant reactions; metals; patch tests.Cutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. The incidence and prevalence of such hypersensitivity reactions are unknown, as the literature lacks longitudinal prospective trials with clear objective criteria and large cross-sectional studies. In the past, it was considered that only a few (<1%) individuals would develop cutaneous complications from implanted metals. This might be an underestimate, as a recent case series showed that up to 5% had metal-related cutaneous complications postimplant (1). Whether they are performing patch testing or not, physicians may be asked for clinical advice regarding metal hypersensitivity. This may occur either prior to implantation or after surgery, when delayed-type hypersensitivity reactions are suspected. Thus, dermatologists should continuously keep updated about this difficult area of contact allergy of growing importance (2).The association between metal allergy and implant failure was reviewed recently (3), and an in-depth review focusing on the association between metal allergy and cardiac devices was performed in 2008 by Honari 4
Allergic complications following insertion of metallic orthopaedic implants include allergic dermatitis reactions but also extracutaneous complications. As metal-allergic patients and/or surgeons may ask dermatologists and allergologists for advice prior to planned orthopaedic implant surgery, and as surgeons may refer patients with complications following total joint arthroplasty for diagnostic work-up, there is a continuous need for updated guidelines. This review presents published evidence for patch testing prior to surgery and proposes tentative diagnostic criteria which clinicians can rely on in the work-up of patients with putative allergic complications following surgery. Few studies have investigated whether subjects with metal contact allergy have increased risk of developing complications following orthopaedic implant insertion. Metal allergy might in a minority increase the risk of complications caused by a delayed-type hypersensitivity reaction. At present, we do not know how to identify the subgroups of metal contact allergic patients with a potentially increased risk of complications following insertion of a metal implant. We recommend that clinicians should refrain from routine patch testing prior to surgery unless the patient has already had implant surgery with complications suspected to be allergic or has a history of clinical metal intolerance of sufficient magnitude to be of concern to the patient or a health provider. The clinical work-up of a patient suspected of having an allergic reaction to a metal implant should include patch testing and possibly in vitro testing. We propose diagnostic criteria for allergic dermatitis reactions as well as noneczematous complications caused by metal implants.
Itch is an aversive sensory experience and while systemic therapies, such as acupuncture, have shown promise in alleviating itch in patients suffering from chronic itch, their antipruritic mechanisms are unknown. As several lines of evidence implicate brain-focused mechanisms, we applied functional magnetic resonance imaging and our validated temperature-modulation itch model to evaluate the underlying brain circuitry supporting allergen-induced itch reduction in atopic dermatitis patients by acupuncture, antihistamine, and respective placebo treatments. Brain response to allergen itch demonstrated phase dependency. During an increasing itch phase, activation was localized in anterior insula and striatum, regions associated with salience/interoception and motivation processing. Once itch reached peak plateau, robust activation was noted in prefrontal cognitive and premotor areas. Acupuncture reduced itch and itch-evoked activation in the insula, putamen, and premotor and prefrontal cortical areas. Neither itch sensation nor itch-evoked brain response was altered following antihistamine or placebo acupuncture. Greater itch reduction following acupuncture was associated with greater reduction in putamen response, a region implicated in motivation and habitual behavior underlying the urge to scratch, specifically implicating this region in acupuncture's antipruritic effects. Understanding brain circuitry underlying itch reduction following acupuncture and related neuromodulatory therapies will significantly impact the development and applicability of novel therapies to reduce an itch.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.