To evaluate the within-session and inter-session repeatability of a new, short-duration transient visual evoked potential (SD-tVEP) device on normal individuals, we tested 30 normal subjects (20/20 visual acuity, normal 24-2 SITA Standard VF) with SD-tVEP. Ten of these subjects had their tests repeated within 1–2 months from the initial visit. Synchronized single-channel EEG was recorded using a modified Diopsys Enfant™ System (Diopsys, Inc., Pine Brook, New Jersey, USA). A checkerboard stimulus was modulated at two reversals per second. Two different contrasts of checkerboard reversal patterns were used: 85% Michelson contrast with a mean luminance of 66.25 cd/m2 and 10% Michelson contrast with a mean luminance of 112 cd/m2. Each test lasted 20 s. Both eyes, independently and together, were tested 10 times (5 times at each contrast level). The following information was identified from the filtered N75-P100-N135 complex: N75 amplitude, N75 latency, P100 amplitude, P100 latency, and Delta Amplitude (N75-P100). The median values for each eye’s five SD-tVEP parameters were calculated and grouped into two data sets based on contrast level. Mean age was 27.3 ± 5.2 years. For OD only, the median (95% confidence intervals) of Delta Amplitude (N75-P100) amplitudes at 10% and 85% contrast were 4.6 uV (4.1–5.9) and 7.1 uV (5.15–9.31). The median P100 latencies were 115.2 ms (112.0–117.7) and 104.0 ms (99.9–106.0). There was little within-session variability for any of these parameters. Intraclass correlation coefficients ranged between 0.64 and 0.98, and within subject coefficients of variation were 3–5% (P100 latency) and 15–30% (Delta Amplitude (N75-P100) amplitude). Bland–Altman plots showed good agreement between the first and fifth test sessions (85% contrast Delta Amplitude (N75-P100) delta amplitude, mean difference, 0.48 mV, 95% CI, −0.18–1.12; 85% contrast P100 latency delay, −0.82 ms, 95% CI, −3.12–1.46; 10% contrast Delta Amplitude (N75-P100) amplitude, 0.58 mV, 95% CI, −0.27–1.45; 10% contrast P100 latency delay, −2.05 mV, 95% CI, −5.12–1.01). The inter-eye correlation and agreement were significant for both SD-tVEP amplitude and P100 latency measurements. For the subset of eyes in which the inter-session repeatability was tested, the intraclass correlation coefficients ranged between 0.71 and 0.86 with good agreement shown on Bland–Altman plots. Short-duration transient VEP technology showed good within-session, inter-session repeatability, and good inter-eye correlation and agreement.
In cases of asymmetric glaucoma, SD-tVEP results correlate significantly with the level of VF damage as measured by MD. In the eyes with more advanced VF loss, reduced SD-tVEP amplitude was associated with decreased macular thickness on OCT. These findings suggest that SD-tVEP may be a fast and objective method to assess or screen for functional damage in glaucomatous eyes.
Purpose. We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. Methods. Thirty-two eyes from 20 subjects with preperimetric glaucoma underwent pattern electroretinogram and optical coherence tomography. Pattern electroretinogram parameters (Magnitude, MagnitudeD, and MagnitudeD/Magnitude ratio) and optic nerve head measurements (rim area, average cup to disc ratio, vertical cup to disc ratio, cup volume, retinal nerve fiber layer thickness sectors, and Bruch’s membrane opening-minimum rim width thickness sectors) were analyzed after controlling for disc area. Results. Magnitude and MagnitudeD were significantly associated with rim area (r ≥ 0.503, p ≤ 0.004 ). All pattern electroretinogram parameters significantly correlated with Bruch’s membrane opening-minimum rim width sectors—temporal superior and nasal inferior (r = 0.400, p = 0.039 )—and retinal nerve fiber layer sectors—superior, nasal superior, and inferior (r ≥ 0.428, p ≤ 0.026 ). Magnitude and MagnitudeD explained an additional 26.8% and 25.2% of variance in rim area (B = 0.174 (95% CI: 0.065, 0.283), p = 0.003 , and B = 0.160 (95% CI: 0.056, 0.265), p = 0.004 ), respectively. MagnitudeD and MagnitudeD/Magnitude ratio explained an additional 13.4% and 12.8% of the variance in Bruch’s membrane opening-minimum rim width global (B = 38.921 [95% CI: 3.872, 73.970], p = 0.031 , and B = 129.024 (95% CI: 9.589, 248.460), p = 0.035 ), respectively. All Bruch’s membrane opening-minimum rim width sectors and retinal nerve fiber layer sectors (nasal superior, nasal inferior, and inferior) were significantly correlated with rim area (r ≥ 0.389, p ≤ 0.045 ). Conclusion. PERG abnormalities can predict rim area loss in preperimetric glaucoma after controlling for disc area. We recommend controlling for disc area to increase diagnostic accuracy in early glaucoma.
Short-duration transient VEP objectively identified decreased visual function and discriminated between healthy and glaucomatous eyes, and also showed good differentiation between healthy eyes and those with early visual field loss. VEP may be useful for early diagnosis of glaucoma.
A method of extracting a temporally bounded component of a composite signal has been developed which minimizes data corruption in signal processing. The composite signal is windowed in the time domain, padding signals are attached, and finally, the conditioned signal is filtered to extract the component of interest. The method has been utilized to extract the Oscillatory Potential (OP) from the Electroretinogram (ERG). ERGs can contain impulse like transients, including flash artifacts and a-b wave transition, which may not be related to the Oscillatory Potential. Such transients will stimulate a filter, yielding its natural (filter) response and thus distort the actual OP signal. To avoid this effect, time-domain windowing and signal conditioning is used to extract the OP from the ERG. The extraction and modeling approach is applied to ERGs obtained from patients with recent monocular central retinal vein occlusion (CRVO). Model parameters clearly differentiate affected from fellow eyes and show subtle differences between eyes with benign and complicated outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.