Use of different CT scanning protocols leads to variations of up to 20% in the HU values. This can result in a mean systematic dose error of 1.5%. Specific conversion tables and automatic CT scanning protocol recognition could reduce dose errors of these types.
The assessment of the exposure to cosmic radiation onboard aircraft is one of the preoccupations of bodies responsible for radiation protection. Cosmic particle flux is significantly higher onboard aircraft than at ground level and its intensity depends on the solar activity. The dose is usually estimated using codes validated by the experimental data. In this paper, a comparison of various codes is presented, some of them are used routinely, to assess the dose received by the aircraft crew caused by the galactic cosmic radiation. Results are provided for periods close to solar maximum and minimum and for selected flights covering major commercial routes in the world. The overall agreement between the codes, particularly for those routinely used for aircraft crew dosimetry, was better than + + + + +20 % from the median in all but two cases. The agreement within the codes is considered to be fully satisfactory for radiation protection purposes.
Positron lifetime measurements are performed in branched polyethylene in the temperature range between −195 and +40 °C. The lifetime spectra are resolved into four components, and corresponding annihilation mechanisms are discussed. Within the temperature range mentioned above four different transitions at −145, −95, −58, and −13 °C can be observed. From the behaviour of the lifetime parameters of the longest‐lived component it is possible to deduce a criterion for the glass transition, which is situated at −13 °C. Additionally, time effects of the lifetime parameters are detected.
A system for dosimetric verification of intensity-modulated radiotherapy (IMRT) treatment plans using absolute calibrated radiographic films is presented. At our institution this verification procedure is performed for all IMRT treatment plans prior to patient irradiation. Therefore clinical treatment plans are transferred to a phantom and recalculated. Composite treatment plans are irradiated to a single film. Film density to absolute dose conversion is performed automatically based on a single calibration film. A software application encompassing film calibration, 2D registration of measurement and calculated distributions, image fusion, and a number of visual and quantitative evaluation utilities was developed. The main topic of this paper is a performance analysis for this quality assurance procedure, with regard to the specification of tolerance levels for quantitative evaluations. Spatial and dosimetric precision and accuracy were determined for the entire procedure, comprising all possible sources of error. The overall dosimetric and spatial measurement uncertainties obtained thereby were 1.9% and 0.8 mm respectively. Based on these results, we specified 5% dose difference and 3 mm distance-to-agreement as our tolerance levels for patient-specific quality assurance for IMRT treatments.
The acceptance and usability of personal protection against solar UV radiation was evaluated in a field study with a group of tinsmiths in Austria. The personal protective measures (PPM) tested involved four categories: shirts, headwear, sunglasses and topically applied sunscreens; at least six different products per category were tested. Recommendations for the "ideal" shirt, headwear, pair of sunglasses and topical sunscreen are given based on data from questionnaires, i.e., from the point of view of the workers, independently from the actual physical level of protection (such as low transmittance or area of coverage) provided. It is argued that in practice it is important to consider the acceptance and usability of protective measures as well as the level of physical protection when providing PPM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.