In recent years, theoretical and experimental efforts have transformed the conventional tilting-pad journal bearing (TPJB) into a smart mechatronic machine element. The application of electromechanical elements into rotating systems makes feasible the generation of controllable forces over the rotor as a function of a suitable control signal. The servovalve input signal and the radial injection pressure are the two main parameters responsible for dynamically modifying the journal oil film pressure and generating active fluid film forces in controllable fluid film bearings. Such fluid film forces, resulting from a strong coupling between hydrodynamic, hydrostatic, and controllable lubrication regimes, can be used either to control or to excite rotor lateral vibrations. If “noninvasive” forces are generated via lubricant fluid film, “in situ” parameter identification can be carried out, enabling evaluation of the mechanical condition of the rotating machine. Using the lubricant fluid film as a “noninvasive calibrated shaker” is troublesome, once several transfer functions among mechanical, hydraulic, and electronic components become necessary. In this framework, the main original contribution of this paper is to show experimentally that the knowledge about the several transfer functions can be bypassed by using output-only identification techniques. This paper links controllable (active) lubrication techniques with operational modal analysis, allowing for in situ parameter identification in rotordynamics, i.e., estimation of damping ratio and natural frequencies. The experimental analysis is carried out on a rigid rotor-level system supported by one single pair of pads. The estimation of damping and natural frequencies is performed using classical experimental modal analysis (EMA) and operational modal analysis (OMA). Very good agreements between the two experimental approaches are found. Maximum values of the main input parameters, namely, servovalve voltage and radial injection pressure, are experimentally found with the objective of defining ranges of noninvasive perturbation forces.
In recent years, theoretical and experimental efforts have transformed the conventional tilting-pad journal bearing (TPJB) into a smart mechatronic machine element. The application of electromechanical elements into rotating systems makes feasible the generation of controllable forces over the rotor as a function of a suitable control signal. The servovalve input signal and the radial injection pressure are the two main parameters responsible for dynamically modifying the journal oil film pressure and generating active fluid film forces in controllable fluid film bearings. Such fluid film forces, resulting from a strong coupling between hydrodynamic, hydrostatic and controllable lubrication regimes, can be used either to control or to excite rotor lateral vibrations. If non-invasive forces are generated via lubricant fluid film, in situ parameter identification can be carried out, enabling evaluation of the mechanical condition of the rotating machine. Using the lubricant fluid film as a non-invasive calibrated shaker is troublesome, once several transfer functions among mechanical, hydraulic and electronic components become necessary. In this framework the main original contribution of this paper is to show experimentally that the knowledge about the several transfer functions can be bypassed by using output-only identification techniques. The manuscript links controllable (active) lubrication techniques with operational modal analysis, allowing for in-situ parameter identification in rotordynamics, i.e. estimation of damping ratio and natural frequencies. The experimental analysis is carried out on a rigid rotor-level system supported by one single pair of pads. The estimation of damping and natural frequencies is performed using classical experimental modal analysis (EMA) and operational modal analysis (OMA). Very good agreements between the two experimental approaches are found. Maximum values of the main input parameters, namely servovalve voltage and radial injection pressure, are experimentally found with the objective of defining ranges of non-invasive perturbation forces.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.