Purpose: To assess the efficacy and survival rate of the Trabectome-mediated ab interno trabeculectomy combined with non-fenestrated Baerveldt glaucoma implant compared with the Baerveldt glaucoma implant alone. Method: In this retrospective comparative case series, 175 eyes undergoing primary glaucoma surgery (Baerveldt–Trabectome [BT] group: 60 eyes and Baerveldt [B] group: 115 eyes) were included. Participants were identified using the procedural terminology codes. Groups were then matched by Coarsened Exact Matching that resulted in the inclusion of 51 eyes in each group. The primary outcome measure was surgical success defined as 5 mmHg < intraocular pressure (IOP) ≤ 21 mmHg, and IOP reduction ≥ 20% from baseline, and no need to reoperation for glaucoma. Secondary outcome measures were IOP, number of glaucoma medications, and best-corrected visual acuity (BCVA). Results: The cumulative probability of success at one year was 61% in the BT group and 50% in the B group. IOP decreased from 23.5 ± 2.4 mmHg at baseline to 14.1 ± 2.7 mmHg at the final follow-up in the BT group (P = 0.001). The corresponding values for the B group were 23.2 ± 2.0 mmHg and 13.9 ± 1.6 mmHg, respectively (P = 0.001). There was no significant difference between the groups in terms of IOP at the final follow-up (P = 0.56). The number of medications at baseline was 2.3 ± 0.3 in both groups. However, the BT group needed fewer drops at all postoperative time intervals and used 1.1 ± 0.3 versus 2.0 ± 0.4 eye drops (group B) at the final follow-up visit (P = 0.004). Eyes in B with phacoemulsification had a significantly higher IOP on day 1 compared to B (23.2 ± 14.3 versus 17.9 ± 11.4, P = 0.041). During the one-year follow-up, 7 (13.7%) patients in BT group and 18 (35.2%) in B group experienced hypotony (P = 0.04). No dangerous hypotony or hypertension occurred in BT group. The mean BCVA at baseline was 0.64 ± 0.85 logMAR and changed to 0.55 ± 0.75 logMAR in BT and B groups, respectively (P = 0.663). The corresponding numbers for the final follow-up visit was 0.72 ± 1.07 and 0.63 ± 0.97 logMAR, respectively (P = 0.668). Conclusion: We observed similar rates of success and IOP reduction using BT and B techniques. BT group needed fewer glaucoma medications. Tube fenestration was unnecessary in BT group resulting in less postoperative ocular hypotony and hypertension. The results of our study indicate that additional trabectome procedure makes Baerveldt glaucoma implant safer, easier to handle, and more predictable in the most vulnerable patients with advanced glaucoma.
Purpose: To evaluate the efficacy and survival rates of trabectome-mediated ab interno trabeculectomy combined with non-fenestrated Baerveldt glaucoma implants (BT) in comparison to Baerveldt glaucoma implant alone (B).Method: A total of 175 eyes undergoing primary glaucoma surgery (60 eyes BT and 115 B) were enrolled in this retrospective comparative case series. Participants were identified using the procedural terminology codes. Groups were then matched using Coarsened Exact Matching (51 eyes in each group). The primary outcome measure was surgical success, defined as 5 mmHg < IOP ≤ 21 mmHg, and IOP reduction ≥ 20% from baseline, and no reoperation for glaucoma. Secondary outcome measures were intraocular pressure, the number of glaucoma medications, and best corrected visual acuity (BCVA).Results: The cumulative probability of success at one year was 61% in BT, and 50% in B. IOP decreased significantly from 23.5±2.4 mmHg at baseline to 14.1±2.7 mmHg at the final follow up in BT (P= 0.001). The corresponding numbers for B were 23.2± 2.0 and 13.9± 1.6, respectively (P= 0.001). There was no significant difference in IOP at the final follow-up (P=0.56). The number of medications at baseline was 2.3±0.3 in both groups. However, BT needed significantly fewer drops at all postoperative time intervals and used 1.1±0.3 (BT) and 2.0±0.4 eye drops (B) at the final follow-up visit (P= 0.004). No dangerous hypotony or hypertension occurred in BT.Conclusion: Similar rates of success and IOP reduction were observed in BT and B. BT needed significantly fewer glaucoma medications. Tube fenestration was not necessary in BT resulting in less postoperative hypotony and hypertension.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.