BackgroundAtrial fibrillation (AF) carries the risk of thrombus formation in the left atrium and especially in the left atrial appendage (LAA). A transoesophageal echocardiography (TOE) is routinely performed in these patients to rule out thrombi before cardioversion or structural interventions like LAA closure or pulmonary vein isolation. However, in a certain number of cases, inconclusive results of the TOE may result. This study was performed to analyse whether the routine use of ultrasound contrast agent (UCA) has an influence on the frequency of thrombus detection.MethodsIn patients with AF who were scheduled for a subsequent interventional procedure, a TOE was initially performed without contrast agent. Then, the TOE was repeated with the use of UCA. The percentage of diagnostic findings regarding the prevalence of thrombus in the LAA with and without UCA were compared (thrombus present (T+), no thrombus (T−) and inconclusive result (T+/−)).Results223 patients were prospectively included into the trial. The numbers of thrombus detection were as follows: without UCA: 17 T+ (7.6%), 154 T− (69.1%), 52 T+/− (23,3%); with UCA: 16 T+ (7.2%), 179 T− (80.3%), 28 T+/− (12.6%; χ2: p<0.01). In 29 examinations (13.0%), the use of UCA had an impact on the subsequent treatment strategy.ConclusionsThe use of UCA during TOE in patients with AF has a significant impact on the subsequent patient management especially due to an improved rule out of LAA thrombi.
IntroductionInterventional closure of the left atrial appendage (LAAC) has been established as an alternative treatment for patients with atrial fibrillation (AF) and an elevated risk of stroke. The WATCHMAN FLX (WM FLX) as the newest WATCHMAN LAAC device differs in several technical characteristics from its precursor, the WATCHMAN V.2.5 (WM V.2.5).MethodsThe data presented here are derived from a retrospective single-centre study. All patients in which an LAAC was performed between February 2017 and March 2021 with either a WM V.2.5 or WM FLX device were included.Results169 patients were included in this study, of whom 95 had been treated with WM V.2.5 and 74 with WM FLX, respectively. Directly after implantation, only minor differences regarding membrane thickness and connector protrusion were noted, whereas no relevant differences were found regarding device sizing, device compression or peridevice leakage, respectively. However, at 3-month follow-up, device compression was significantly reduced in WM FLX indicating a continued device expansion which was paralleled by a reduced number of peridevice leakage in comparison to WM V.2.5. Additionally, the combined clinical endpoint of death, stroke/transistoric ischaemic attack, tamponade, device embolisation, device-related thrombosis or peridevice leakage was reduced in WM FLX.ConclusionLAAC using the WM FLX device results in a continued device expansion over the first 3 months based on differences in radial force in comparison to WM V.2.5. This is accompanied by a reduction in adverse clinical endpoints.
Objectives: The aim of this study was to determine whether the application of a CT-based preplanning algorithm might allow abstaining from TEE during LAAC. Background: LAAC is an established treatment alternative for patients with atrial fibrillation. Today, most LAAC procedures are guided by TEE, which, however, leads to the need for patient sedation and might even cause direct harm to the patient. CT-based preplanning of the LAAC procedure, in combination with technical improvements in device design and interventional experience, might allow abstaining from TEE. Methods: Fluoro-FLX is a prospective single-center study to evaluate how often TEE leads to a procedural change during interventional LAAC if a dedicated CT planning algorithm is applied. The study hypothesis is that under these circumstances, a sole fluoroscopy-guided LAAC is an alternative to a TEE-guided approach. All procedures are preplanned by cardiac CT and, finally, guided by fluoroscopy only, while TEE is carried out in the background during the intervention for safety reasons. Results: In none of the 31 consecutive patients did TEE lead to a change in the preplanned fluoroscopy-guided LAAC (success ratio: 1.00; CI: 0.94–1.00), thereby meeting the primary endpoint (performance goal: 0.90). There were no procedure-related adverse cardiac or cerebrovascular events (no pericardial effusion, TIA, stroke, systemic embolism, device embolism, death). Conclusions: Our data suggest that it is feasible to perform LAAC under sole fluoroscopic guidance if preplanning is performed using cardiac CT. This might be worth considering, especially in patients who are at high risk for TEE-related adverse events.
A multilevel decomposition approach for the preliminary design of a High Speed Civil Transport Aircraft wing structure is described. The wing design is decomposed into three levels. The top level uses the FLOPS aircraft synthesis program to generate preliminary weights, mission, and performance information. The optimization criterion is productivity
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.